Mercurial > public > ostc4
annotate Documentations/dump-rte.cfg @ 686:b1e24513b83e Betatest
Bugfix Battery charge complete event:
In previous version it could happen that the battery charge state was set to 100% even the battery was not completly charged. Rootcause was that the external charger IC signals sometimes completion because e.g. the connection between charger unit and OSTC is disconnected within a short time slot. This may happen while the user is trying to get the OSTC in a good charging position. To avoid this the state machine now checks the voltage everytime for valid charging complete range before a charging complete is signaled.
author | Ideenmodellierer |
---|---|
date | Fri, 05 Aug 2022 14:56:17 +0200 |
parents | 01cc5959f199 |
children |
rev | line source |
---|---|
34 | 1 #! openocd -f |
2 # Define the prob used: | |
3 source [find interface/stlink-v2.cfg] | |
4 set WORKAREASIZE 0x8000 | |
5 transport select hla_swd | |
6 | |
7 # Reset options | |
8 set ENABLE_LOW_POWER 1 | |
9 set STOP_WATCHDOG 1 | |
10 reset_config srst_only srst_nogate connect_assert_srst | |
11 | |
12 # Seelct the right chip | |
13 set CHIPNAME stm32f411RETx | |
14 set CONNECT_UNDER_RESET 1 | |
15 source [find target/stm32f4x.cfg] | |
16 | |
17 # Allow to continue execution after a connection: | |
18 init_reset run | |
19 | |
20 #puts "Flash banks:" | |
21 #flash banks | |
22 | |
23 #puts "Reading..." | |
24 #flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000 | |
25 | |
26 #puts "Done." | |
27 #exit |