Bugfix Battery charge complete event:
In previous version it could happen that the battery charge state was set to 100% even the battery was not completly charged. Rootcause was that the external charger IC signals sometimes completion because e.g. the connection between charger unit and OSTC is disconnected within a short time slot. This may happen while the user is trying to get the OSTC in a good charging position. To avoid this the state machine now checks the voltage everytime for valid charging complete range before a charging complete is signaled.
author | Ideenmodellierer |
---|---|
date | Fri, 05 Aug 2022 14:56:17 +0200 |
parents | 01cc5959f199 |
children |
line wrap: on
line source
#! openocd -f # Define the prob used: source [find interface/stlink-v2.cfg] set WORKAREASIZE 0x8000 transport select hla_swd # Reset options set ENABLE_LOW_POWER 1 set STOP_WATCHDOG 1 reset_config srst_only srst_nogate connect_assert_srst # Seelct the right chip set CHIPNAME stm32f411RETx set CONNECT_UNDER_RESET 1 source [find target/stm32f4x.cfg] # Allow to continue execution after a connection: init_reset run #puts "Flash banks:" #flash banks #puts "Reading..." #flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000 #puts "Done." #exit