view Documentations/dump-rte.cfg @ 686:b1e24513b83e Betatest

Bugfix Battery charge complete event: In previous version it could happen that the battery charge state was set to 100% even the battery was not completly charged. Rootcause was that the external charger IC signals sometimes completion because e.g. the connection between charger unit and OSTC is disconnected within a short time slot. This may happen while the user is trying to get the OSTC in a good charging position. To avoid this the state machine now checks the voltage everytime for valid charging complete range before a charging complete is signaled.
author Ideenmodellierer
date Fri, 05 Aug 2022 14:56:17 +0200
parents 01cc5959f199
children
line wrap: on
line source

#! openocd -f
# Define the prob used:
source [find interface/stlink-v2.cfg]
set WORKAREASIZE 0x8000
transport select hla_swd

# Reset options
set ENABLE_LOW_POWER 1
set STOP_WATCHDOG 1
reset_config srst_only srst_nogate connect_assert_srst

# Seelct the right chip
set CHIPNAME stm32f411RETx
set CONNECT_UNDER_RESET 1
source [find target/stm32f4x.cfg]

# Allow to continue execution after a connection:
init_reset run

#puts "Flash banks:"
#flash banks

#puts "Reading..."
#flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000

#puts "Done."
#exit