Mercurial > public > ostc4
view Documentations/dump-rte.cfg @ 302:eba8d1eb5bef cleanup-4
bugfix, cleanup: keep both is_ambient_pressure_close_to_surface in sync
The CPU1 firmware used 40cm of water pressure, and the RTE used 1m of
water pressure to detect between diving and surface state. This is
simply wrong, and can lead to small, rounding like, errors.
Use 1m water pressure as "official" depth things count as diving.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
author | Jan Mulder <jlmulder@xs4all.nl> |
---|---|
date | Mon, 20 May 2019 10:13:44 +0200 |
parents | 01cc5959f199 |
children |
line wrap: on
line source
#! openocd -f # Define the prob used: source [find interface/stlink-v2.cfg] set WORKAREASIZE 0x8000 transport select hla_swd # Reset options set ENABLE_LOW_POWER 1 set STOP_WATCHDOG 1 reset_config srst_only srst_nogate connect_assert_srst # Seelct the right chip set CHIPNAME stm32f411RETx set CONNECT_UNDER_RESET 1 source [find target/stm32f4x.cfg] # Allow to continue execution after a connection: init_reset run #puts "Flash banks:" #flash banks #puts "Reading..." #flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000 #puts "Done." #exit