Mercurial > public > ostc4
view Documentations/dump-rte.cfg @ 645:e58f81cb25a7
Small changes in charger state handling:
Charger debounce time has been reduced to 5 seconds and the detection time of charger removal has been reduced to 15 second to be able to provide a faster feedback to the user.
In addition the battery stage reset has been added (only relevant for a getState function which is not used within the firmware at the moment.
author | Ideenmodellierer |
---|---|
date | Tue, 13 Apr 2021 19:18:32 +0200 |
parents | 01cc5959f199 |
children |
line wrap: on
line source
#! openocd -f # Define the prob used: source [find interface/stlink-v2.cfg] set WORKAREASIZE 0x8000 transport select hla_swd # Reset options set ENABLE_LOW_POWER 1 set STOP_WATCHDOG 1 reset_config srst_only srst_nogate connect_assert_srst # Seelct the right chip set CHIPNAME stm32f411RETx set CONNECT_UNDER_RESET 1 source [find target/stm32f4x.cfg] # Allow to continue execution after a connection: init_reset run #puts "Flash banks:" #flash banks #puts "Reading..." #flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000 #puts "Done." #exit