Bugfix Line order of info screen with flip screen active:
In the previous version the order of the line in flipping mode (top to bottom) was 6,5,4,3,2,1 instead of 1,2,3,4,5,6. This effected the compass calibration as well as the sensor info view. The problem was solved by adapting the Y calculation.
In addition the size of the SensorInfo screen was corrected to avoid clipping issues in flipped mode.
author | Ideenmodellierer |
---|---|
date | Wed, 11 Oct 2023 17:49:19 +0200 |
parents | 01cc5959f199 |
children |
line wrap: on
line source
#! openocd -f # Define the prob used: source [find interface/stlink-v2.cfg] set WORKAREASIZE 0x8000 transport select hla_swd # Reset options set ENABLE_LOW_POWER 1 set STOP_WATCHDOG 1 reset_config srst_only srst_nogate connect_assert_srst # Seelct the right chip set CHIPNAME stm32f411RETx set CONNECT_UNDER_RESET 1 source [find target/stm32f4x.cfg] # Allow to continue execution after a connection: init_reset run #puts "Flash banks:" #flash banks #puts "Reading..." #flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000 #puts "Done." #exit