Reactivate compass parameter stored in NVM:
The calibration parameters are stored in NVM but the automatic restore function during startup was no longer active. As result the compass needed to be calibration after every RTE update. In addition compass HW was detected at every startup causing some i2c "trouble" because of adressing not available devices. The compass HW info is now stored together with the calibration parameters to avoid i2C problems.
author | Ideenmodellierer |
---|---|
date | Wed, 25 Nov 2020 20:16:20 +0100 |
parents | 01cc5959f199 |
children |
line wrap: on
line source
#! openocd -f # Define the prob used: source [find interface/stlink-v2.cfg] set WORKAREASIZE 0x8000 transport select hla_swd # Reset options set ENABLE_LOW_POWER 1 set STOP_WATCHDOG 1 reset_config srst_only srst_nogate connect_assert_srst # Seelct the right chip set CHIPNAME stm32f411RETx set CONNECT_UNDER_RESET 1 source [find target/stm32f4x.cfg] # Allow to continue execution after a connection: init_reset run #puts "Flash banks:" #flash banks #puts "Reading..." #flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000 #puts "Done." #exit