Devbugfix UART buffer cleaning:
In the previous version a buffer cleaning function was used which resets the ringbuffer read index. As result the processing of data was stopped until the DMA write comes to the index 0. When reaching it the complete buffer was proceeded including possibly invalid data.
The usage of the cleanbuffer function was replaced by the flush buffer function (meaning the data is discarded but the data index is maintained). There was already a function for this. Because the function was 99% the same as the read function, it was integrated into the ReadData function. Calling the function with parameter flush = 1 will result in a buffer flush.
The workaround of the previous revision was updated to only be applied in case a DiveO2 sensor is operated in stand alone mode.
author | Ideenmodellierer |
---|---|
date | Wed, 29 Jan 2025 17:21:20 +0100 (7 weeks ago) |
parents | 01cc5959f199 |
children |
line wrap: on
line source
#! openocd -f # Define the prob used: source [find interface/stlink-v2.cfg] set WORKAREASIZE 0x8000 transport select hla_swd # Reset options set ENABLE_LOW_POWER 1 set STOP_WATCHDOG 1 reset_config srst_only srst_nogate connect_assert_srst # Seelct the right chip set CHIPNAME stm32f411RETx set CONNECT_UNDER_RESET 1 source [find target/stm32f4x.cfg] # Allow to continue execution after a connection: init_reset run #puts "Flash banks:" #flash banks #puts "Reading..." #flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000 #puts "Done." #exit