Mercurial > public > ostc4
annotate Documentations/dump-rte.cfg @ 261:cc2406b835ff bm-3
Bugfix: do not reset saturation on surfacing
Commit 822416168585 introduced a subtle bug. On surfacing, the value of
saturation was reset to 0. This is prefect proof why global data is a
dangerous thing, and subtle changes can introduce seemingly unrelated
bugs.
While it would be much better to factor out as much as possible global
data, the fix here does not do that. Simply, the bug is fixed without
touching the rather complex gTissue_nitrogen_bar/gTissue_helium_bar
handling.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
author | Jan Mulder <jlmulder@xs4all.nl> |
---|---|
date | Tue, 23 Apr 2019 13:05:20 +0200 |
parents | 01cc5959f199 |
children |
rev | line source |
---|---|
34 | 1 #! openocd -f |
2 # Define the prob used: | |
3 source [find interface/stlink-v2.cfg] | |
4 set WORKAREASIZE 0x8000 | |
5 transport select hla_swd | |
6 | |
7 # Reset options | |
8 set ENABLE_LOW_POWER 1 | |
9 set STOP_WATCHDOG 1 | |
10 reset_config srst_only srst_nogate connect_assert_srst | |
11 | |
12 # Seelct the right chip | |
13 set CHIPNAME stm32f411RETx | |
14 set CONNECT_UNDER_RESET 1 | |
15 source [find target/stm32f4x.cfg] | |
16 | |
17 # Allow to continue execution after a connection: | |
18 init_reset run | |
19 | |
20 #puts "Flash banks:" | |
21 #flash banks | |
22 | |
23 #puts "Reading..." | |
24 #flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000 | |
25 | |
26 #puts "Done." | |
27 #exit |