Mercurial > public > ostc4
annotate Documentations/dump-disc.cfg @ 538:b1eee27cd02b
BugFix firmware downgrade to version with less settings:
If a downgrade to a firmware version using less setting parameter were done then the settings had been reset to the default values. Root cause was that only increased number of settings was accepted by the read function. Because the layout of the setting structure is fixed (only bytes attached, no change in the order of data values) a downgrade just discarding the no longer used settings is possible => Updated read function to handle reduction of setting parameters.
author | Ideenmodellierer |
---|---|
date | Sat, 10 Oct 2020 13:51:44 +0200 |
parents | 01cc5959f199 |
children |
rev | line source |
---|---|
34 | 1 #! openocd -f |
2 # Define the prob used: | |
3 source [find interface/stlink-v2.cfg] | |
4 set WORKAREASIZE 0x8000 | |
5 transport select hla_swd | |
6 | |
7 # Reset options | |
8 set ENABLE_LOW_POWER 1 | |
9 set STOP_WATCHDOG 1 | |
10 reset_config srst_only srst_nogate connect_assert_srst | |
11 | |
12 # Seelct the right chip | |
13 set CHIPNAME stm32f427IIT6 | |
14 set CONNECT_UNDER_RESET 1 | |
15 source [find target/stm32f4x.cfg] | |
16 | |
17 # Allow to continue execution after a connection: | |
18 init_reset run | |
19 | |
20 puts "Flash banks:" | |
21 flash banks | |
22 | |
23 #puts "Reading FIRMWARE..." | |
24 # Requires OpenOCD 0.10.0 / released January 2017 ? | |
25 #flash dump_image CPU1-DISC-dump.hex 0x00000000 0x8000 | |
26 | |
27 #puts "Done." | |
28 exit |