SPI_Start_single_TxRx_with_Master evaluated the incoming data for a condition to send device instead of life data. In case of invalid input data this may cause unintended transmission of device data => now lifedata is send if incoming data is expected to be invalid
The SPI timeout monitoring was done at the beginning of the mode loop. A timeout may have been detected even if meanwhile valid data was received (this is evaluated at x20ms) => Moved the timeout monitoring after the handling of incoming data