log

age author description
22 months ago Ideenmodellierer Update digital O2 sensor information:
22 months ago Ideenmodellierer Sensor status support for multiplexed DiveO2 sensors:
22 months ago Ideenmodellierer Update real multiplexer implementation:
22 months ago Ideenmodellierer Discovery<=>SmallCPU inferface update:
22 months ago Ideenmodellierer Added UART multiplexer support for DiveO2:
22 months ago heinrichsweikamp Zusammenf?hren
22 months ago heinrichsweikamp This is only showing if one of the compass views is visible. It should make it possible to verify that a correct heading is set as the user can see the compass readout when pushing the button. (mikeller)
22 months ago heinrichsweikamp Add support for a configurable compass declination in a range of -99 to 99 degrees.
23 months ago heinrichsweikamp Add a shortcuts to change the setpoint to the loop to the 'normal' display when diving. It is only shown when diving in CCR mode and on the loop.
23 months ago heinrichsweikamp more menu items for the compass menu: Delete bearing, and reset to land based bearing. I have also re-enabled the real time bearing display in the menu - makes it easier to set the correct bearing. (mikeller)
23 months ago heinrichsweikamp Menu shortcut for bailout / return to circuit when diving in CCR mode (mikeller)
23 months ago izzni Fix character truncation when screen is flipped. This was causing the dive computer to lock up when in English Units with the screen flipped when the first decompression stop is shown using FONT_105.
23 months ago heinrichsweikamp Revised automatic setpoint change. The proposed approach is essentially the approach used by most controllers of eCCR ('upshift' on descent, 'downshift' on ascent), so that the OSTC4 when used as a backup computer for eCCR will make the changes at the same time as the eCCR itself.
23 months ago heinrichsweikamp CCR overview in surface mode. Makes it easy to quickly check that all settings (mode, setpoints, diluent, scrubber timer) are correct when preparing to dive (also makes the OC gas list available in surface mode for the same reason).
23 months ago heinrichsweikamp Deactivation of the 'fallback' option when the CCR mode is set to 'Fixed' - this makes it a little clearer that the option has no influence in this mode.
23 months ago heinrichsweikamp 1.6.2 release
24 months ago heinrichsweikamp Update build for testing
24 months ago heinrichsweikamp change button default responsiveness to 100
24 months ago heinrichsweikamp After a firmware update, use the factory settings for button sensitivity if these exist, the default settings otherwise.
2023-03-27 heinrichsweikamp Update build for testing
2023-03-26 heinrichsweikamp increase HAL_Delay to 10ms for cold-start-button reset
2023-03-26 heinrichsweikamp Preparing a 1.6.2 release candidate
2023-03-21 heinrichsweikamp Fix/handle negative scrubber timer values
2023-03-21 heinrichsweikamp Quit simualted dives after the dive time set in the SIM tab.
2023-03-17 heinrichsweikamp Some compass improvements from mikeller
2023-03-15 heinrichsweikamp - Colours for scrubber display when time remaining falls below a threshold value
2023-03-07 Ideenmodellierer Dev Bugfix: ignore analog out of bounds limits for DiveO2 sensor:
2023-03-07 Ideenmodellierer Added visualization of CO2 during dive:
2023-03-07 Ideenmodellierer Cleanup display of multiple warnings in T3 (Big font) view:
2023-03-07 Ideenmodellierer Only show autodetection in sensor menu if external interface is present: