log

age author description
Sat, 17 Aug 2019 18:44:43 +0200 ideenmodellierer Show actual instead of surface (30minute old) pressure if the actual differs significant (e.g. in plane or during pressure testing) PressureMeasure_Improvment
Tue, 13 Aug 2019 21:46:26 +0200 ideenmodellierer Use average calculation for pressure: precondition was that pressure values jittered +- 10 HPa from one capture (once a second) to the other. Basically pressure is measured several times a second => using these values in an additional history calculation reduces the jitter down to +-1 per second PressureMeasure_Improvment
Sun, 04 Aug 2019 11:01:06 +0200 heinrichsweikamp building a 1.5 v1.5.0 release
Sat, 20 Jul 2019 10:44:01 +0200 heinrichsweikamp add update files for testing purposes
Thu, 18 Jul 2019 14:26:56 +0000 heinrichsweikamp Merged in Ideenmodellierer/ostc4/I2C_Improvment (pull request #30)
Wed, 17 Jul 2019 22:43:51 +0200 ideenmodellierer Added plausibility check for pressure values I2C_Improvment
Wed, 17 Jul 2019 22:43:16 +0200 ideenmodellierer Added check of configuration. I2C_Improvment