Mercurial > public > ostc4
log
age | author | description |
---|---|---|
Sat, 17 Aug 2019 19:03:47 +0200 | ideenmodellierer | Apply averaging to pressure measurement: In pre versions calculated pressure value jittered +/-10hPa. Since we measure the pressure several time a second but only use one value a second, calc average including not used values PressureMeasure_Improvment |
Sat, 17 Aug 2019 18:57:15 +0200 | ideenmodellierer | Added function to avoid divemode activation during Landing: PressureMeasure_Improvment |
Sat, 17 Aug 2019 18:47:08 +0200 | ideenmodellierer | Set Max value for pressure offset to 50mBar (20mBar before) PressureMeasure_Improvment |
Sat, 17 Aug 2019 18:44:43 +0200 | ideenmodellierer | Show actual instead of surface (30minute old) pressure if the actual differs significant (e.g. in plane or during pressure testing) PressureMeasure_Improvment |