log

age author description
Mon, 19 Aug 2019 11:42:31 +0000 heinrichsweikamp Merged in Ideenmodellierer/ostc4/PressureMeasure_Improvment (pull request #31)
Sat, 17 Aug 2019 19:03:47 +0200 ideenmodellierer Apply averaging to pressure measurement: In pre versions calculated pressure value jittered +/-10hPa. Since we measure the pressure several time a second but only use one value a second, calc average including not used values PressureMeasure_Improvment
Sat, 17 Aug 2019 18:57:15 +0200 ideenmodellierer Added function to avoid divemode activation during Landing: PressureMeasure_Improvment
Sat, 17 Aug 2019 18:47:08 +0200 ideenmodellierer Set Max value for pressure offset to 50mBar (20mBar before) PressureMeasure_Improvment
Sat, 17 Aug 2019 18:44:43 +0200 ideenmodellierer Show actual instead of surface (30minute old) pressure if the actual differs significant (e.g. in plane or during pressure testing) PressureMeasure_Improvment
Tue, 13 Aug 2019 21:46:26 +0200 ideenmodellierer Use average calculation for pressure: precondition was that pressure values jittered +- 10 HPa from one capture (once a second) to the other. Basically pressure is measured several times a second => using these values in an additional history calculation reduces the jitter down to +-1 per second PressureMeasure_Improvment
Sun, 04 Aug 2019 11:01:06 +0200 heinrichsweikamp building a 1.5 v1.5.0 release
Sat, 20 Jul 2019 10:44:01 +0200 heinrichsweikamp add update files for testing purposes