Mercurial > public > ostc4
changeset 669:c1e203ffb478 Betatest
Rework charge cycle:
The charge counter is increasing decreasing also if the real value is maybe not defined (definition is done for example by a completed charging cycle). This caused some problems with invalid displayed charge per centage values. To avoid this the state of an unknow counter value was introduced. The indication is done by converting the counter into a negativ value.
author | Ideenmodellierer |
---|---|
date | Sat, 12 Mar 2022 22:49:09 +0100 |
parents | 079bb5b22c06 |
children | 7a352b449055 |
files | Small_CPU/Inc/batteryGasGauge.h |
diffstat | 1 files changed, 6 insertions(+), 0 deletions(-) [+] |
line wrap: on
line diff
--- a/Small_CPU/Inc/batteryGasGauge.h Sat Mar 12 22:48:45 2022 +0100 +++ b/Small_CPU/Inc/batteryGasGauge.h Sat Mar 12 22:49:09 2022 +0100 @@ -35,6 +35,8 @@ #define BATTERY_ENDOF_CHARGE_VOLTAGE (4.05f) #define BATTERY_CHARGER_CONNECTED_VOLTAGE (4.2f) +#define BATTERY_CHARGE_UNKNOWN (-1.0f) + void init_battery_gas_gauge(void); float get_voltage(void); @@ -45,6 +47,10 @@ void battery_gas_gauge_set(float percentage); uint8_t battery_gas_gauge_CheckConfigOK(void); +uint8_t battery_gas_gauge_isChargeValueValid(void); +void battery_gas_gauge_setChargeValueValid(void); + + #ifdef __cplusplus } #endif