Mercurial > public > ostc4
changeset 449:91a939915bfa minor_improvments
Added initialization of bottle sensor data age counter
author | ideenmodellierer |
---|---|
date | Mon, 23 Mar 2020 21:14:54 +0100 |
parents | f7c66593ab82 |
children | b2f8a39c11ea |
files | Discovery/Src/tCCR.c |
diffstat | 1 files changed, 10 insertions(+), 0 deletions(-) [+] |
line wrap: on
line diff
--- a/Discovery/Src/tCCR.c Mon Mar 23 21:13:52 2020 +0100 +++ b/Discovery/Src/tCCR.c Mon Mar 23 21:14:54 2020 +0100 @@ -53,6 +53,8 @@ #define HUD_RX_START_DELAY_MS (500u) /* Delay for start of RX function to avoid start of reception while a transmission is ongoing. */ /* Based on an assumed cycle time by the sensor of 1 second. Started at time of last RX */ +#define BOTTLE_SENSOR_TIMEOUT (6000u) /* signal pressure budget as not received after 10 minutes (6000 * 100ms) */ + /* Private variables ---------------------------------------------------------*/ static SIrLink receiveHUD[2]; static uint8_t boolHUDdata = 0; @@ -290,7 +292,15 @@ void tCCR_init(void) { + uint8_t loop; + StartListeningToUART_HUD = 1; + + SDiveState* pDiveData = stateRealGetPointerWrite(); + for(loop=0;loop<(2*NUM_GASES+1);loop++) + { + pDiveData->lifeData.bottle_bar_age_MilliSeconds[loop] = BOTTLE_SENSOR_TIMEOUT; + } }