log Discovery/Src/settings.c @ 799:1e3c12d772eb

age author description
Mon, 31 Jul 2023 20:00:06 +0200 Ideenmodellierer Expanded Sensor map structure:
Sat, 05 Aug 2023 11:52:08 +0200 heinrichsweikamp Avoid a configuration warning after the firmware upgrade by disabling automatic setpoint switching. This makes sure the user's automatic setpoint configuration is not overwritten by the validity checks if the settings are not in the correct spots for the new configuration. Users will have to manually re-create the automatic setpoint switching configuration in the new format;
Tue, 04 Jul 2023 14:39:06 +0200 heinrichsweikamp Define explicit setpoints for low / high / deco. Add an option to delay the switch to SPlow until all decompression has been cleared. (mikeller)
Thu, 18 May 2023 09:49:17 +0200 heinrichsweikamp Add support for a configurable compass declination in a range of -99 to 99 degrees.
Thu, 13 Apr 2023 09:35:43 +0200 heinrichsweikamp 1.6.2 release
Wed, 12 Apr 2023 09:24:44 +0200 heinrichsweikamp After a firmware update, use the factory settings for button sensitivity if these exist, the default settings otherwise.
Sun, 26 Mar 2023 11:27:29 +0200 heinrichsweikamp Preparing a 1.6.2 release candidate
Tue, 21 Mar 2023 12:57:37 +0100 heinrichsweikamp Fix/handle negative scrubber timer values
Wed, 15 Mar 2023 09:18:07 +0100 heinrichsweikamp - Colours for scrubber display when time remaining falls below a threshold value
Thu, 02 Feb 2023 17:35:38 +0100 Ideenmodellierer Added button lock after wakeup in surface mode:
Sun, 15 Jan 2023 21:48:34 +0100 Ideenmodellierer Optical sensor as default:
Sat, 14 Jan 2023 20:41:36 +0100 Ideenmodellierer Added sensor map to Firmware <=> RTE inferface:
Sun, 20 Nov 2022 20:42:33 +0100 Ideenmodellierer Increased version number and set beta label
Tue, 08 Nov 2022 21:16:17 +0100 Ideenmodellierer Extension scrubber time:
Fri, 19 Aug 2022 11:27:44 +0200 heinrichsweikamp 1.6.0 release Betatest
Fri, 05 Aug 2022 15:10:10 +0200 Ideenmodellierer Increased version numbers: Betatest
Sat, 12 Mar 2022 14:57:54 +0100 heinrichsweikamp increase version numbers for upcomming release Betatest
Tue, 14 Dec 2021 15:36:10 +0100 heinrichs weikamp PSCR Mode Betatest
Mon, 26 Apr 2021 15:03:04 +0200 heinrichs weikamp Update release date
Sun, 25 Apr 2021 20:41:19 +0200 Ideenmodellierer Introduced new menu tab for addition CCR options:
Mon, 19 Apr 2021 20:34:53 +0200 Ideenmodellierer Allow setpoint starting at 0.4 ppO2:
Mon, 19 Apr 2021 20:19:32 +0200 Ideenmodellierer Automatik setpoint change:
Tue, 30 Mar 2021 10:34:12 +0200 heinrichs weikamp Compile with ENABLE_CHARGER_STATUS_V2
Thu, 25 Feb 2021 12:20:43 +0100 heinrichsweikamp add build for testing, advance to FW1.5.7, RTE is unchanged since 1.5.6
Fri, 05 Feb 2021 14:53:50 +0100 heinrichsweikamp Update RTE required value for release
Fri, 05 Feb 2021 14:50:05 +0100 heinrichsweikamp 1.5.6 release v1.5.6 release
Thu, 17 Dec 2020 09:52:12 +0100 heinrichsweikamp Update current build, "RTErequired" value and release date
Tue, 24 Nov 2020 13:22:23 -0600 izzni -Add 12HR Time Support
Sun, 15 Nov 2020 19:53:09 +0100 Ideenmodellierer Added O2 sensor source and calibration parameters to setting structure
Sun, 08 Nov 2020 18:38:53 +0100 Ideenmodellierer Make sure motion detection settings are set to default values: