Mercurial > public > ostc4
graph
-
Merged in Ideenmodellierer/ostc4/FlightMode_Improvment (pull request #32)Sun, 06 Oct 2019 11:58:36 +0000, by heinrichsweikamp
-
Decrease ManualExitDiveCounter in surface mode FlightMode_ImprovmentThu, 03 Oct 2019 21:39:28 +0200, by ideenmodellierer
-
Minor changes to debug view FlightMode_ImprovmentThu, 03 Oct 2019 21:34:52 +0200, by ideenmodellierer
-
Added option to manually leave dive mode to system menu FlightMode_ImprovmentThu, 03 Oct 2019 21:33:47 +0200, by ideenmodellierer
-
Added function to support manuel exit of dive mode FlightMode_ImprovmentThu, 03 Oct 2019 21:30:16 +0200, by ideenmodellierer
-
Added function to evaluate the state of the surface pressure history memory FlightMode_ImprovmentThu, 03 Oct 2019 21:26:46 +0200, by ideenmodellierer
-
Removed not used wireless menu items FlightMode_ImprovmentTue, 01 Oct 2019 19:58:58 +0200, by ideenmodellierer
-
Added compile switch to enable debug view option in system menu FlightMode_ImprovmentTue, 01 Oct 2019 19:43:30 +0200, by ideenmodellierer
-
Removed averaging of pressure and temperatur values FlightMode_ImprovmentTue, 01 Oct 2019 19:13:41 +0200, by ideenmodellierer
-
change max. allowed surface pressure to 1030hPa (As in the small OSTC)Sun, 06 Oct 2019 14:07:51 +0200, by heinrichsweikamp
-
Merged in Ideenmodellierer/ostc4/PressureMeasure_Improvment (pull request #31)Mon, 19 Aug 2019 11:42:31 +0000, by heinrichsweikamp
-
Apply averaging to pressure measurement: In pre versions calculated pressure value jittered +/-10hPa. Since we measure the pressure several time a second but only use one value a second, calc average including not used values PressureMeasure_ImprovmentSat, 17 Aug 2019 19:03:47 +0200, by ideenmodellierer
-
Added function to avoid divemode activation during Landing: PressureMeasure_ImprovmentSat, 17 Aug 2019 18:57:15 +0200, by ideenmodellierer
-
Set Max value for pressure offset to 50mBar (20mBar before) PressureMeasure_ImprovmentSat, 17 Aug 2019 18:47:08 +0200, by ideenmodellierer
-
Show actual instead of surface (30minute old) pressure if the actual differs significant (e.g. in plane or during pressure testing) PressureMeasure_ImprovmentSat, 17 Aug 2019 18:44:43 +0200, by ideenmodellierer
-
Use average calculation for pressure: precondition was that pressure values jittered +- 10 HPa from one capture (once a second) to the other. Basically pressure is measured several times a second => using these values in an additional history calculation reduces the jitter down to +-1 per second PressureMeasure_ImprovmentTue, 13 Aug 2019 21:46:26 +0200, by ideenmodellierer