Mercurial > public > ostc4
graph
-
Code cleanup pressure plausibility check: Improve_Button_SleepWed, 13 May 2020 21:56:35 +0200, by ideenmodellierer
-
Bugfix unintended else condition: Improve_Button_SleepWed, 13 May 2020 21:27:30 +0200, by ideenmodellierer
-
Development option only: Show Pressure update for a short time in the custom field (as warning) Improve_Button_SleepTue, 12 May 2020 23:03:50 +0200, by ideenmodellierer
-
Only switch between "no fly" and "desaturation" in case there is desaturation time left: Improve_Button_SleepTue, 12 May 2020 23:03:29 +0200, by ideenmodellierer
-
Balance value of button responsitivness were not considered during firmware startup: Improve_Button_SleepTue, 12 May 2020 22:54:19 +0200, by ideenmodellierer
-
Added error detection for reading of ADC values in sleep mode: Improve_Button_SleepTue, 12 May 2020 22:42:52 +0200, by ideenmodellierer
-
Do not signal power on reset in case of a "warm" reset: Improve_Button_SleepTue, 12 May 2020 22:39:18 +0200, by ideenmodellierer
-
Merged in janlmulder/ostc4/fix-bat-2 (pull request #44)Tue, 28 Apr 2020 15:37:47 +0000, by heinrichsweikamp
-
bugfix: implement battery charge percentage in dive header fix-bat-2Wed, 22 Apr 2020 13:08:57 +0200, by Jan Mulder
-
Merged in Ideenmodellierer/ostc4/Improve_Logtansfer (pull request #42)Wed, 15 Apr 2020 07:01:11 +0000, by heinrichsweikamp
-
Removed no longer needed reset profile function: Improve_LogtansferTue, 14 Apr 2020 19:45:34 +0200, by ideenmodellierer
-
Moved and deactivated analyse sample buffer switch: Improve_LogtansferTue, 14 Apr 2020 19:44:19 +0200, by ideenmodellierer
-
Cmd Get profile: transmit dummy profile if necessary Improve_LogtansferTue, 14 Apr 2020 19:29:23 +0200, by ideenmodellierer
-
Removed invalidate header function because it is no lonnger needed Improve_LogtansferTue, 14 Apr 2020 19:27:04 +0200, by ideenmodellierer
-
Compare profile length from header and sample data to identify valid profiles Improve_LogtansferTue, 14 Apr 2020 19:22:56 +0200, by ideenmodellierer
-
Added compile switch to handle additional data during raw header request: Improve_LogtansferMon, 13 Apr 2020 16:00:54 +0200, by ideenmodellierer
-
Added function to transfer sample buffer: Improve_LogtansferSun, 12 Apr 2020 21:02:34 +0200, by ideenmodellierer
-
Power-down Bluetooth on COMM exitWed, 08 Apr 2020 16:34:54 +0200, by heinrichsweikamp
-
Merged in Ideenmodellierer/ostc4/minor_improvments (pull request #41)Mon, 30 Mar 2020 13:16:11 +0000, by heinrichsweikamp
-
merged default into minor_improvments minor_improvmentsSun, 29 Mar 2020 21:55:00 +0200, by Ideenmodellierer
-
Activated reset of sample information within header data at time of sector erasing: minor_improvmentsSun, 29 Mar 2020 21:39:57 +0200, by ideenmodellierer
-
Added ppO2 to dummy profile data: minor_improvmentsSat, 28 Mar 2020 21:41:47 +0100, by ideenmodellierer
-
Eliminated some minor warnings minor_improvmentsTue, 24 Mar 2020 22:32:48 +0100, by ideenmodellierer
-
Transfer a dummy profile in case of missing sample information: minor_improvmentsTue, 24 Mar 2020 22:14:16 +0100, by ideenmodellierer
-
Reactivated samples for bottle pressure information: minor_improvmentsTue, 24 Mar 2020 22:12:08 +0100, by ideenmodellierer
-
Reactivated samples for bottle pressure information: minor_improvmentsTue, 24 Mar 2020 22:08:29 +0100, by ideenmodellierer
-
Added compile variant enabling the reset of profile sample information: minor_improvmentsTue, 24 Mar 2020 21:59:38 +0100, by ideenmodellierer
-
Added compile variant enabling the reset of profile sample information: minor_improvmentsTue, 24 Mar 2020 21:59:11 +0100, by ideenmodellierer
-
Allocate received bar value to active gas (was static allocated to gas[1]) minor_improvmentsTue, 24 Mar 2020 21:49:52 +0100, by ideenmodellierer
-
Added new compile switches for variants: minor_improvmentsTue, 24 Mar 2020 21:48:27 +0100, by ideenmodellierer
-
Added initialization of bottle sensor data age counter minor_improvmentsMon, 23 Mar 2020 21:14:54 +0100, by ideenmodellierer
-
Added compile switch to show voltage parallel to charge status percantage minor_improvmentsMon, 23 Mar 2020 21:13:52 +0100, by ideenmodellierer
-
Added compile switch var firmware variant which does trust the memory log => does not check the log consistency at startu (used for test purpose) minor_improvmentsMon, 23 Mar 2020 21:10:02 +0100, by ideenmodellierer
-
Introduced configuration header for variant managment: minor_improvmentsThu, 05 Mar 2020 22:31:50 +0100, by ideenmodellierer
-
Removed duplicated definition: minor_improvmentsThu, 05 Mar 2020 22:27:55 +0100, by ideenmodellierer
-
Introduced enum for lower left corner view selection: minor_improvmentsSat, 29 Feb 2020 22:27:29 +0100, by ideenmodellierer
-
Introduced enum for lower left corner view selection: minor_improvmentsSat, 29 Feb 2020 22:27:04 +0100, by ideenmodellierer
-
Introduced enum for lower left corner view selection: minor_improvmentsSat, 29 Feb 2020 22:25:20 +0100, by ideenmodellierer
-
fix potential issue with >255 dives in the logbookSun, 01 Mar 2020 10:06:45 +0100, by heinrichsweikamp
-
Added tag v1.5.3 release for changeset 5b4c78c36b04Thu, 27 Feb 2020 09:13:25 +0100, by heinrichsweikamp
-
update the 1.5.3 for testsMon, 24 Feb 2020 15:17:54 +0100, by heinrichsweikamp
-
Merged in Ideenmodellierer/ostc4/Improve_BatteryGasGauge (pull request #40)Mon, 24 Feb 2020 07:58:37 +0000, by heinrichsweikamp
-
Moved power on detection to RTE: Improve_BatteryGasGaugeSun, 23 Feb 2020 21:18:49 +0100, by ideenmodellierer
-
Bugfix display battery voltage in maintainance menu: Improve_BatteryGasGaugeSun, 23 Feb 2020 21:17:17 +0100, by ideenmodellierer
-
Reduced timeout for common UART communication: Improve_BatteryGasGaugeSun, 23 Feb 2020 21:13:28 +0100, by ideenmodellierer
-
Detect startup after power off: Improve_BatteryGasGaugeSun, 23 Feb 2020 21:09:56 +0100, by ideenmodellierer