Bugfix ppo2 display in simulator mode:
In the previous version a wrong ppo2 value was display if a digital O2 sensor was used. Rootcause was that the calibration data of the analog sensors was used. To fix this a default calibration coefficient is used (calibration is done within the sensor => no need to store it in OSTC) if the sensor is identified as digital O2 sensor.
| author | Ideenmodellierer |
|---|---|
| date | Thu, 30 Jan 2025 21:24:46 +0100 |
| parents | 4093ac18b25c |
| children |
line wrap: on
line source
/* Define to prevent recursive inclusion -------------------------------------*/ #ifndef PRESSURE_H #define PRESSURE_H #include <stdint.h> uint8_t init_pressure(void); void pressure_set_offset (float pressureOffset, float temperatureOffset); uint8_t pressure_update(void); void pressure_update_alternating(void); uint8_t is_init_pressure_done(void); HAL_StatusTypeDef pressure_sensor_get_pressure_raw(void); HAL_StatusTypeDef pressure_sensor_get_temperature_raw(void); void pressure_calculation(void); float get_temperature(void); float get_pressure_mbar(void); float get_surface_mbar(void); uint8_t is_surface_pressure_stable(void); float set_last_surface_pressure_stable(void); void init_surface_ring(uint8_t force); void update_surface_pressure(uint8_t call_rhythm_seconds); uint32_t demo_modify_temperature_and_pressure(int32_t divetime_in_seconds, uint8_t subseconds, float ceiling_mbar); #endif /* PRESSURE_H */