bugfix, cleanup: keep both is_ambient_pressure_close_to_surface in sync
The CPU1 firmware used 40cm of water pressure, and the RTE used 1m of
water pressure to detect between diving and surface state. This is
simply wrong, and can lead to small, rounding like, errors.
Use 1m water pressure as "official" depth things count as diving.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
author | Jan Mulder <jlmulder@xs4all.nl> |
---|---|
date | Mon, 20 May 2019 10:13:44 +0200 |
parents | 5f11787b4f42 |
children |
line wrap: on
line source
/** ****************************************************************************** * @file adc.h * @author heinrichs weikamp gmbh * @version V0.0.1 * @date 11-Dec-2014 * @brief ADC ambient light sensor ****************************************************************************** * @attention * * <h2><center>© COPYRIGHT(c) 2014 heinrichs weikamp</center></h2> * ****************************************************************************** */ /* Define to prevent recursive inclusion -------------------------------------*/ #ifndef ADC_H #define ADC_H #ifdef __cplusplus extern "C" { #endif /* Includes ------------------------------------------------------------------*/ #include <stdint.h> uint16_t get_ambient_light_level(void); void adc_ambient_light_sensor_get_data(void); void ADCx_Init(void); void ADCx_DeInit(void); #ifdef __cplusplus } #endif #endif /* ADC_H */ /************************ (C) COPYRIGHT heinrichs weikamp *****END OF FILE****/