Switch source of o2 sensor data depending on availability of external ADC:
Dependig on the HW configuration provided by RTE the data vields for o2 voltage values are derived from the optical or the external ADC interface. TODO: Add manual selection to O2 menu to enable manuel switching.
author
Ideenmodellierer
date
Thu, 12 Nov 2020 19:54:58 +0100 (2020-11-12)
parents
0e7c16dd774d
children
line source
# How to Make an Uploadable Firmware File for the OSTC4 #+ −
+ −
Generated BIN files from the SMT32 Workbench need modification in order to be installed via the OSTC Companion onto the OSTC4. + −
+ −
## Build Command Line Tools ##+ −
+ −
These can be found in /ostc4pack (For Windows, CPP sources available)+ −
+ −
## Run the Tools Manually ##+ −
+ −
1. Copy generated BIN files (From the Release or debug directory) into /ostc4pack. Or: Modify .bat files to point to your Release or debug directory.+ −
2. run step1_create_OSTC_RTE_upload.bat and/or step1_create_OSTC4_firmware_upload_bin.bat (Depending on which part you made changes)+ −
3. run step2_create_OSTC4update_bin.bat to create final OSTC4update_xxxxxx.bin, with xxxxxx being the current date in YYMMDD format. This will add important checksums required for the OSTC4's bootloader to accept the file.+ −
+ −
## Upload this file with the OSTC Companion software to the OSTC4 ##+ −
+ −
See http://forum.heinrichsweikamp.com/read.php?7,19186 on how to get and use the "OSTC companion"+ −