Mercurial > public > ostc4
view Discovery/Inc/configuration.h @ 556:eb2060caca7d
Switch source of o2 sensor data depending on availability of external ADC:
Dependig on the HW configuration provided by RTE the data vields for o2 voltage values are derived from the optical or the external ADC interface. TODO: Add manual selection to O2 menu to enable manuel switching.
author | Ideenmodellierer |
---|---|
date | Thu, 12 Nov 2020 19:54:58 +0100 |
parents | 02e7e11fdbe8 |
children | 280c11153080 |
line wrap: on
line source
/////////////////////////////////////////////////////////////////////////////// /// -*- coding: UTF-8 -*- /// /// \file Discovery/Inc/configuration.h /// \brief Header file for variant specific firmware adaptations at compile time /// \author heinrichs weikamp gmbh /// \date 29-February-2020 /// /// $Id$ /////////////////////////////////////////////////////////////////////////////// /// \par Copyright (c) 2014-2020 Heinrichs Weikamp gmbh /// /// This program is free software: you can redistribute it and/or modify /// it under the terms of the GNU General Public License as published by /// the Free Software Foundation, either version 3 of the License, or /// (at your option) any later version. /// /// This program is distributed in the hope that it will be useful, /// but WITHOUT ANY WARRANTY; without even the implied warranty of /// MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the /// GNU General Public License for more details. /// /// You should have received a copy of the GNU General Public License /// along with this program. If not, see <http://www.gnu.org/licenses/>. ////////////////////////////////////////////////////////////////////////////// #ifndef CONFIGURATION_HEADER #define CONFIGURATION_HEADER /* Enable this to make the simulator write a logbook entry */ /* #define SIM_WRITES_LOGBOOK 1 */ /* Enable this for support of optical bottle pressure interface */ /* #define ENABLE_BOTTLE_SENSOR */ /* Enable this to show voltage in parallel to charge state */ /* #define ALWAYS_SHOW_VOLTAGE */ /* Enable this to skip coplete scan of dive log during startup */ #define TRUST_LOG_CONSISTENCY /* Enable this to transfer additional data list last dive ID and last sample index during raw data requests */ /* define SEND_DATA_DETAILS */ /* Enable to activate a menu item in reset menu which provide sample ring analysis / repair functionality */ /* #define ENABLE_ANALYSE_SAMPLES */ /* Enable to have access to the debug view options (turn on / off via menu instead of compile switch) */ /* #define HAVE_DEBUG_VIEW */ /* Enable to have access to the motion control selection menu */ /* #define ENABLE_MOTION_CONTROL */ /* Enable to have option to hide not needed gases from dive views */ /* #define ENABLE_UNUSED_GAS_HIDING */ #endif