view ostc4pack/README.linux @ 747:df0d43da1614

Added pressure compensation to CO2 detection: A pressure compensation is needed if the ExplorIR shall be used under extended pressure conditions. The procedure recommended by the application note has been integrated. To keep things simple the focus of the CO2 measurement is not the precision, as it is needed for the decompression calculation, but the indication of a critical increase of CO2 in the breathing loop. That's why only a lookup table with 1000ppm steps has been implemented instead of calculating the polynom for every measurement.
author Ideenmodellierer
date Sun, 05 Mar 2023 22:06:47 +0100
parents 9c77cfe8c2b2
children
line wrap: on
line source

README.linux
------------

1. Compile the pack utilities

cd src
make checksum_final_add_fletcher
make OSTC4pack_V4

2. Edit create_full_update_bin.sh

Set BUILD_PATH to the location where you build the individual parts
of the firmware using the OpenSTM23 IDE. 

Set BUILD_TYPE the either Debug or Release (or any other build style you 
defined in the OpenSTM23 IDE).

Set the "build project names" as defined in the OpenSTM23 IDE.

3. Simpy run create_full_update_bin.sh

Run it in the ostc4pack folder of the repository, and a file with name
like OSTC4_<date>.bin is created containg the individual blobs.