view Documentations/dump-rte.cfg @ 831:da632300e7d4 Evo_2_23

Activated work gas for (p)scr mode: In previous version setting of change depth for work (travel) gases was not possible. For (p)scr operation this is not possible. Work gases will not be considered for deco calculation. In addition the first gas will be handled as "deco" gas. This allows switching back to the first gas in case the current gas becomes no longer breathable (ppo2 low).
author Ideenmodellierer
date Thu, 16 Nov 2023 20:36:35 +0100
parents 01cc5959f199
children
line wrap: on
line source

#! openocd -f
# Define the prob used:
source [find interface/stlink-v2.cfg]
set WORKAREASIZE 0x8000
transport select hla_swd

# Reset options
set ENABLE_LOW_POWER 1
set STOP_WATCHDOG 1
reset_config srst_only srst_nogate connect_assert_srst

# Seelct the right chip
set CHIPNAME stm32f411RETx
set CONNECT_UNDER_RESET 1
source [find target/stm32f4x.cfg]

# Allow to continue execution after a connection:
init_reset run

#puts "Flash banks:"
#flash banks

#puts "Reading..."
#flash dump_image CPU2-RTE-dump.hex 0x00000000 0x8000

#puts "Done."
#exit