Improvment battery charger visualization: In the previous version the green flash (charge complete) was shown even battery had not reached 100% charge. Root cause was that the pin signaling the end of charge could be raised for other reasons then a full battery. The new version will show the green flash only in case the battery is rated as full. In addition the graph visualization has been updated to continously progress. In the previous version it only progressed in case the charge value changed. Especially at charging start the charger is doing some battery evaluation which does not increase the charge state. In such a case the graph seemed to be frozen.
author Ideenmodellierer
date Tue, 07 May 2024 21:20:33 +0200
parents 5f11787b4f42
children
line wrap: on
line source

# How to Create From Scratch a Project for _CPU1-Upper_ Code #

The main CPU (aka. _CPU1 Discovery_) firmware is splitted in two parts:
- The proper _CPU1 Discovery_ firmware, with the main code.
- The _protected upper memory_ firmware, which is programmed during _OSTC4_ production, and contains (amongst other things) code used to upload and install firmware upgrades.

## Make a specific project ##

Follow the same procedure than for [CPU1-Discovery](Detailed CPU1-Discovery Project.md), (same processor, same includes) but include the `CPU1-Upper` source directory.

**
NOT FINISHED YET... BE PATIENT
**