Debounce fallback warning: In previous versions the fallback option (automatical setting of a fixed setpoint) was only done for communication timeout scenario in combination with a HUD. It is now also applied in case all sensors are rated as out of bounds. The signaling of the fallback warning (including optional automatic setpoint change) is now done taking a 5 seconds debounds time into account. In case a fallback warning is active, then the only way to reset it is by selecting a new setpoint or by changing the sensor configuration (no change compared to previous implementation
author Ideenmodellierer
date Wed, 24 Feb 2021 21:03:54 +0100
parents 4093ac18b25c
children
line wrap: on
line source

/* Define to prevent recursive inclusion -------------------------------------*/
#ifndef PRESSURE_H
#define PRESSURE_H

#include <stdint.h>

uint8_t init_pressure(void);
void pressure_set_offset (float pressureOffset, float temperatureOffset);

uint8_t pressure_update(void);
void pressure_update_alternating(void);

uint8_t is_init_pressure_done(void);

HAL_StatusTypeDef  pressure_sensor_get_pressure_raw(void);
HAL_StatusTypeDef  pressure_sensor_get_temperature_raw(void);
void pressure_calculation(void);

float get_temperature(void);
float get_pressure_mbar(void);
float get_surface_mbar(void);

uint8_t is_surface_pressure_stable(void);
float set_last_surface_pressure_stable(void);

void init_surface_ring(uint8_t force);
void update_surface_pressure(uint8_t call_rhythm_seconds);

uint32_t demo_modify_temperature_and_pressure(int32_t divetime_in_seconds, uint8_t subseconds, float ceiling_mbar);

#endif /* PRESSURE_H */