BugFix firmware downgrade to version with less settings:
If a downgrade to a firmware version using less setting parameter were done then the settings had been reset to the default values. Root cause was that only increased number of settings was accepted by the read function. Because the layout of the setting structure is fixed (only bytes attached, no change in the order of data values) a downgrade just discarding the no longer used settings is possible => Updated read function to handle reduction of setting parameters.
author | Ideenmodellierer |
---|---|
date | Sat, 10 Oct 2020 13:51:44 +0200 |
parents | 02e7e11fdbe8 |
children | 280c11153080 |
line wrap: on
line source
/////////////////////////////////////////////////////////////////////////////// /// -*- coding: UTF-8 -*- /// /// \file Discovery/Inc/configuration.h /// \brief Header file for variant specific firmware adaptations at compile time /// \author heinrichs weikamp gmbh /// \date 29-February-2020 /// /// $Id$ /////////////////////////////////////////////////////////////////////////////// /// \par Copyright (c) 2014-2020 Heinrichs Weikamp gmbh /// /// This program is free software: you can redistribute it and/or modify /// it under the terms of the GNU General Public License as published by /// the Free Software Foundation, either version 3 of the License, or /// (at your option) any later version. /// /// This program is distributed in the hope that it will be useful, /// but WITHOUT ANY WARRANTY; without even the implied warranty of /// MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the /// GNU General Public License for more details. /// /// You should have received a copy of the GNU General Public License /// along with this program. If not, see <http://www.gnu.org/licenses/>. ////////////////////////////////////////////////////////////////////////////// #ifndef CONFIGURATION_HEADER #define CONFIGURATION_HEADER /* Enable this to make the simulator write a logbook entry */ /* #define SIM_WRITES_LOGBOOK 1 */ /* Enable this for support of optical bottle pressure interface */ /* #define ENABLE_BOTTLE_SENSOR */ /* Enable this to show voltage in parallel to charge state */ /* #define ALWAYS_SHOW_VOLTAGE */ /* Enable this to skip coplete scan of dive log during startup */ #define TRUST_LOG_CONSISTENCY /* Enable this to transfer additional data list last dive ID and last sample index during raw data requests */ /* define SEND_DATA_DETAILS */ /* Enable to activate a menu item in reset menu which provide sample ring analysis / repair functionality */ /* #define ENABLE_ANALYSE_SAMPLES */ /* Enable to have access to the debug view options (turn on / off via menu instead of compile switch) */ /* #define HAVE_DEBUG_VIEW */ /* Enable to have access to the motion control selection menu */ /* #define ENABLE_MOTION_CONTROL */ /* Enable to have option to hide not needed gases from dive views */ /* #define ENABLE_UNUSED_GAS_HIDING */ #endif