cleanup, RTE: factor out scheduleCheck_pressure_reached_dive_mode_level
The detection of the start of dive mode is conceptually simple (when the
pressure sensor reaches a certain threshold, we are diving). This said,
there are multiple implementations over the entire code base to answer
the question: are we diving?
This commit factors out scheduleCheck_pressure_reached_dive_mode_level used
only in the RTE, in favor of is_ambient_pressure_close_to_surface, which
is used in both RTE and CPU1 firmware.
I had a little hope that is would fix the 1 second difference between
the initial stopwatch and the divetime, but it does not.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
author | Jan Mulder <jlmulder@xs4all.nl> |
---|---|
date | Mon, 20 May 2019 10:05:27 +0200 |
parents | bfcea6e2ab3f |
children |
line wrap: on
line source
/////////////////////////////////////////////////////////////////////////////// /// -*- coding: UTF-8 -*- /// /// \file Discovery/Inc/vpm.h /// \brief Varying Permeability Model (VPM) Decompression Program /// \author Heinrichs Weikamp /// \date 23.04.2013 /// /// $Id$ /////////////////////////////////////////////////////////////////////////////// /// \par Copyright (c) 2014-2018 Heinrichs Weikamp gmbh /// /// This program is free software: you can redistribute it and/or modify /// it under the terms of the GNU General Public License as published by /// the Free Software Foundation, either version 3 of the License, or /// (at your option) any later version. /// /// This program is distributed in the hope that it will be useful, /// but WITHOUT ANY WARRANTY; without even the implied warranty of /// MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the /// GNU General Public License for more details. /// /// You should have received a copy of the GNU General Public License /// along with this program. If not, see <http://www.gnu.org/licenses/>. ////////////////////////////////////////////////////////////////////////////// #ifndef VPM_H #define VPM_H #include "buehlmann.h" #include "data_central.h" extern long vpm_time_calc_begin; enum DECOLIST{DECOSTOPS,FUTURESTOPS,BAILOUTSTOPS, OFF = -1}; // order is important!! enum VPM_CALC_STATUS{CALC_END, CALC_BEGIN, CALC_CRITICAL, CALC_FINAL_DECO, CALC_NDL }; float schreiner_equation__2(float *initial_inspired_gas_pressure,float *rate_change_insp_gas_pressure,float *interval_time_minutes, const float *gas_time_constant,float *initial_gas_pressure); int vpm_calc(SLifeData* pINPUT, SDiveSettings* diveSettings, SVpm* pVPM, SDecoinfo* pDECOINFO, int calc_what); void vpm_saturation_after_ascent(SLifeData* input); extern const float helium_time_constant[16]; extern const float nitrogen_time_constant[16]; float vpm_get_CNS(void); #endif /* VPM_H */