Ignore automatic setpoint changes during ascend: In the previous version setpoint changes which have been configured for descending were considered for deco calculation in case one or more additional diluents have been activated. This procedure does not fit to the common way to keep setpoint high till end of the dive in order to get rid of the deco time. In the new implementation the OSTC assumes that the current setpoint is used till the end of the dive.
author Ideenmodellierer
date Thu, 02 Jun 2022 20:24:59 +0200
parents 822416168585
children
line wrap: on
line source

///////////////////////////////////////////////////////////////////////////////
/// -*- coding: UTF-8 -*-
///
/// \file   Discovery/Inc/buehlmann.h
/// \brief	ZHL16+GF decompression algorithm.
/// \author Heinrichs Weikamp
/// \date   2018
///
/// $Id$
///////////////////////////////////////////////////////////////////////////////
/// \par Copyright (c) 2014-2018 Heinrichs Weikamp gmbh
///
///     This program is free software: you can redistribute it and/or modify
///     it under the terms of the GNU General Public License as published by
///     the Free Software Foundation, either version 3 of the License, or
///     (at your option) any later version.
///
///     This program is distributed in the hope that it will be useful,
///     but WITHOUT ANY WARRANTY; without even the implied warranty of
///     MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
///     GNU General Public License for more details.
///
///     You should have received a copy of the GNU General Public License
///     along with this program.  If not, see <http://www.gnu.org/licenses/>.
//////////////////////////////////////////////////////////////////////////////

#ifndef BUEHLMANN_H
#define BUEHLMANN_H

#include "data_central.h"

void buehlmann_init(void);
void buehlmann_calc_deco(SLifeData* pLifeData, SDiveSettings * pDiveSettings, SDecoinfo * pDecoInfo);
void buehlmann_ceiling_calculator(SLifeData* pLifeData, SDecoinfo * pDecoInfo);
void buehlmann_super_saturation_calculator(SLifeData* pLifeData, SDecoinfo * pDecoInfo);
float buehlmann_get_gCNS(void);

#endif /* BUEHLMANN_H */