view ostc4pack/README.linux @ 577:9bb9a52d6ae5

Handle o2 voltage values < 0.5mV as invalid: Values < 0.5mv will now be handled as ppo2 = 0Bar to avaid problems (e.g. by negativ values) in the decompression calculation. In the custom display sensors with low voltage are show using '-'
author Ideenmodellierer
date Sun, 29 Nov 2020 22:58:11 +0100
parents 9c77cfe8c2b2
children
line wrap: on
line source

README.linux
------------

1. Compile the pack utilities

cd src
make checksum_final_add_fletcher
make OSTC4pack_V4

2. Edit create_full_update_bin.sh

Set BUILD_PATH to the location where you build the individual parts
of the firmware using the OpenSTM23 IDE. 

Set BUILD_TYPE the either Debug or Release (or any other build style you 
defined in the OpenSTM23 IDE).

Set the "build project names" as defined in the OpenSTM23 IDE.

3. Simpy run create_full_update_bin.sh

Run it in the ostc4pack folder of the repository, and a file with name
like OSTC4_<date>.bin is created containg the individual blobs.