view ostc4pack/README.linux @ 222:9b4b3decd9ba div-fixes-3

Bugfix: correct presentation error in tissues custom view The green vertical line in the N2/He bars show the inspired partial pressures of the respective gasses. Obviously, the tissue partial pressure is always lower on an initial descent, than the inspired partial pressure of the respective gas. Further, when for a given depth, the inspired partial pressure is equal to the tissue partial pressure, the tissue gets fully saturated, so the bars stop at the green line. For N2, a simple presentation error was present. As the body is always saturated with about 75% of N2 (according to the Buelmann algorithm), the tissue N2 was shifted left for that amount, but the inspired N2 line was not. So, the N2 green vertical line was too far to the right. Corrected this. Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
author Jan Mulder <jlmulder@xs4all.nl>
date Fri, 29 Mar 2019 14:00:43 +0100
parents 9c77cfe8c2b2
children
line wrap: on
line source

README.linux
------------

1. Compile the pack utilities

cd src
make checksum_final_add_fletcher
make OSTC4pack_V4

2. Edit create_full_update_bin.sh

Set BUILD_PATH to the location where you build the individual parts
of the firmware using the OpenSTM23 IDE. 

Set BUILD_TYPE the either Debug or Release (or any other build style you 
defined in the OpenSTM23 IDE).

Set the "build project names" as defined in the OpenSTM23 IDE.

3. Simpy run create_full_update_bin.sh

Run it in the ostc4pack folder of the repository, and a file with name
like OSTC4_<date>.bin is created containg the individual blobs.