Only use deco gas for calculation if option is enabled: The gas menu meanwhile provides the possibility to select a gas for deco (having the gas switching reminder visible) without the need to visualize the reduced deco time. If the visualization of the deco considering all gas changes is wanted then this may be enabled by selecting the gas additionaly for deco calculation.
author Ideenmodellierer
date Tue, 02 Jul 2024 19:24:03 +0200
parents c3dd461ca3f9
children
line wrap: on
line source

/**
  ******************************************************************************
  * @file    uartProtocol_Co2.h
  * @author  heinrichs weikamp gmbh
  * @version V0.0.1
  * @date    31-Jul-2023
  * @brief	 Interface functionality to handle external, UART based CO2 sensors
  *
  @verbatim
  ==============================================================================
                        ##### How to use #####
  ==============================================================================
  @endverbatim
  ******************************************************************************
  * @attention
  *
  * <h2><center>&copy; COPYRIGHT(c) 2014 heinrichs weikamp</center></h2>
  *
  ******************************************************************************
  */

/* Define to prevent recursive inclusion -------------------------------------*/
#ifndef UART_PROTOCOL_CO2_H
#define UART_PROTOCOL_CO2_H

#ifdef __cplusplus
 extern "C" {
#endif

/* Includes ------------------------------------------------------------------*/
#include "configuration.h"
#include "stm32f4xx_hal.h"

 typedef enum
  {
	UART_CO2_INIT = 0,		/* Default Status for every sensor type */
	UART_CO2_IDLE,			/* sensor detected and no communication pending */
	UART_CO2_ERROR,
 	UART_CO2_SETUP = 10,	/* collecting data needed to be read out of the sensor once at startup */
  	UART_CO2_OPERATING,		/* normal operation */
	UART_CO2_CALIBRATE		/* request calibration */
  } uartCO2Status_t;

  typedef enum
  {
  	CO2RX_Ready= 0,					/* Initial state */
 	CO2RX_DetectStart,					/* validate start byte */
 	CO2RX_SelectData,					/* Data contained in this frame */
  	CO2RX_Data0,						/* Process incoming data */
 	CO2RX_Data1,
 	CO2RX_Data2,
 	CO2RX_Data3,
 	CO2RX_Data4,
 	CO2RX_Data5,
 	CO2RX_Data6,
 	CO2RX_Data7,
 	CO2RX_Data8,
 	CO2RX_Data9,
 	CO2RX_Data10,
 	CO2RX_Data11,
 	CO2RX_Data12,
 	CO2RX_DataComplete
  } receiveStateCO2_t;


 typedef enum
 {
 	CO2CMD_MODE_POLL,		/* Set operation mode of sensor to polling => only send data if requested */
 	CO2CMD_MODE_STREAM,		/* Set operation mode of sensor to streaming => send data every two seconds */
 	CO2CMD_CALIBRATE,		/* Calibrate sensor */
 	CO2CMD_GETSCALE,		/* Get scaling factor */
 	CO2CMD_GETDATA			/* Read sensor data */
 } co2SensorCmd_t;


void uartCo2_Control(void);
void uartCo2_ProcessData(uint8_t data);
void uartCo2_SendCmd(uint8_t CO2Cmd, uint8_t *cmdString, uint8_t *cmdLength);
uint8_t uartCo2_isSensorConnected();

#endif /* UART_PROTOCOL_CO2_H */