view Documentations/dump-disc.cfg @ 189:8b8074080d7b avg-temp

Bugfix: average temperature on arrival from RTE instead of display time This commit is heavily inspired by commits 05c770dc2911 and ecb71521d004. Reading the code, it was clear that a display time averaging process for measured temperature was implemented as was fixed for current depth display in the two mentioned commits. The bug for the late averaging of the temperature is, obviously, not as prominent as the current depth fault. The bug fixed here was nothing more than a visual glitch when first selecting the temperature display in the lower left corner (by default at the start of the dive, or by manually selecting it during the dive using the left button). So, to summarize. A small visual glitch fix, but more important, more consistent data handling and code. Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
author Jan Mulder <jlmulder@xs4all.nl>
date Fri, 15 Mar 2019 15:04:57 +0100
parents 01cc5959f199
children
line wrap: on
line source

#! openocd -f
# Define the prob used:
source [find interface/stlink-v2.cfg]
set WORKAREASIZE 0x8000
transport select hla_swd

# Reset options
set ENABLE_LOW_POWER 1
set STOP_WATCHDOG 1
reset_config srst_only srst_nogate connect_assert_srst

# Seelct the right chip
set CHIPNAME stm32f427IIT6
set CONNECT_UNDER_RESET 1
source [find target/stm32f4x.cfg]

# Allow to continue execution after a connection:
init_reset run

puts "Flash banks:"
flash banks

#puts "Reading FIRMWARE..."
# Requires OpenOCD 0.10.0 / released January 2017 ?
#flash dump_image CPU1-DISC-dump.hex 0x00000000 0x8000

#puts "Done."
exit