Deactivate deco gas calculation option:
In the previous version had the option to consider a deco gas i the calculation or not. Reason for this was to have the automatic gas suggestion available while the deco calculation is still based on the current gas.
This might cause a critical situation in case the diver is not sure if the option is active or not => In the new version the TTS / deco is always calculated considering all deco gases.
////////////////////////////////////////////////////////////////////////////////// -*- coding: UTF-8 -*-////// \file Common/Inc/decom.h/// \brief This code is used to calculate desat, calculated by RTE and send to Firmware/// \author Heinrichs Weikamp/// \date 22-Feb-2016////// $Id$////////////////////////////////////////////////////////////////////////////////// \par Copyright (c) 2014-2018 Heinrichs Weikamp gmbh////// This program is free software: you can redistribute it and/or modify/// it under the terms of the GNU General Public License as published by/// the Free Software Foundation, either version 3 of the License, or/// (at your option) any later version.////// This program is distributed in the hope that it will be useful,/// but WITHOUT ANY WARRANTY; without even the implied warranty of/// MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the/// GNU General Public License for more details.////// You should have received a copy of the GNU General Public License/// along with this program. If not, see <http://www.gnu.org/licenses/>.//////////////////////////////////////////////////////////////////////////////#ifndef DECOM_H#define DECOM_H#include "data_central.h"# define WATER_VAPOUR_PRESSURE (0.0493f) // Schreiner 1971void decom_get_inert_gases(const float ambient_pressure_bar,const SGas* pGas, float* fraction_nitrogen, float* fraction_helium );void decom_tissues_exposure(int period_in_seconds, SLifeData* pLifeData);void decom_tissues_exposure2(int period_in_seconds, SGas* pActualGas, float pressure_ambient_bar, float *tissue_N2_selected_stage, float *tissue_He_selected_stage);float decom_schreiner_equation(float *initial_inspired_gas_pressure, float *rate_change_insp_gas_pressure, float *interval_time_minutes, const float *gas_time_constant, float *initial_gas_pressure);void decom_reset_with_1000mbar(SLifeData * pLifeData);void decom_reset_with_ambientmbar(float ambient, SLifeData * pLifeData);void decom_tissues_exposure_stage_schreiner(int period_in_seconds, SGas* pGas, float starting_ambient_pressure_bar, float ending_ambient_pressure_bar, float* pTissue_nitrogen_bar, float* pTissue_helium_bar);void decom_CreateGasChangeList(SDiveSettings* pInput, const SLifeData* lifeData);uint8_t decom_tissue_test_tolerance(float* Tissue_nitrogen_bar, float* Tissue_helium_bar, float GF_value, float depth_in_bar_absolute);void decom_tissues_desaturation_time(const SLifeData* pLifeData, SLifeData2* pOutput);void test_decom_CreateGasChangeList(void);float decom_calc_ppO2(const float ambiant_pressure_bar, const SGas* pGas);float decom_calc_SimppO2(float ambiant_pressure_bar, const SGas* pGas);float decom_calc_SimppO2_O2based(float ambiant_pressure_bar, uint8_t O2PerCent, float factor);void decom_oxygen_calculate_otu(float* oxygen_otu, float pressure_oxygen_real);void decom_oxygen_calculate_otu_degrade(float* oxygen_otu, long seconds_since_last_dive);void decom_oxygen_calculate_cns_degrade(float* oxygen_cns, long seconds_since_last_dive);void decom_oxygen_calculate_cns(float* oxygen_cns, float pressure_oxygen_real);void decom_oxygen_calculate_cns_stage_SchreinerStyle(int period_in_seconds, SGas* pGas, float starting_ambient_pressure_bar, float ending_ambient_pressure_bar, float* oxygen_cns);void decom_oxygen_calculate_cns_exposure(int period_in_seconds, SGas* pActualGas, float pressure_ambient_bar, float* oxygen_cns);uint8_t decom_get_actual_deco_stop(SDiveState* pDiveState);// wird nur in smallCPU verwendet:int decom_calc_desaturation_time(float* Tissue_nitrogen_bar, float* Tissue_helium_bar, float surface_pressure_bar);#endif /* DECOM_H */