view Documentations/dump-disc.cfg @ 403:6f30f2011667

We got one report of false/freezd depth reading when jumping into 2m depth instantaneously. The "PRESSURE_JUMP_VALID_MBAR" threshold was removed, the new behaviour was tested in the pressure tank intensively and it's simply better/more reliable without this threshold.
author heinrichsweikamp
date Wed, 08 Jan 2020 15:35:15 +0100
parents 01cc5959f199
children
line wrap: on
line source

#! openocd -f
# Define the prob used:
source [find interface/stlink-v2.cfg]
set WORKAREASIZE 0x8000
transport select hla_swd

# Reset options
set ENABLE_LOW_POWER 1
set STOP_WATCHDOG 1
reset_config srst_only srst_nogate connect_assert_srst

# Seelct the right chip
set CHIPNAME stm32f427IIT6
set CONNECT_UNDER_RESET 1
source [find target/stm32f4x.cfg]

# Allow to continue execution after a connection:
init_reset run

puts "Flash banks:"
flash banks

#puts "Reading FIRMWARE..."
# Requires OpenOCD 0.10.0 / released January 2017 ?
#flash dump_image CPU1-DISC-dump.hex 0x00000000 0x8000

#puts "Done."
exit