Debounce fallback warning:
In previous versions the fallback option (automatical setting of a fixed setpoint) was only done for communication timeout scenario in combination with a HUD. It is now also applied in case all sensors are rated as out of bounds. The signaling of the fallback warning (including optional automatic setpoint change) is now done taking a 5 seconds debounds time into account.
In case a fallback warning is active, then the only way to reset it is by selecting a new setpoint or by changing the sensor configuration (no change compared to previous implementation
author | Ideenmodellierer |
---|---|
date | Wed, 24 Feb 2021 21:03:22 +0100 |
parents | d24395f7c939 |
children |
line wrap: on
line source
<?xml version="1.0" encoding="UTF-8"?> <projectDescription> <name>OSTC4_Firmware</name> <comment></comment> <projects> </projects> <buildSpec> <buildCommand> <name>org.eclipse.cdt.managedbuilder.core.genmakebuilder</name> <triggers>clean,full,incremental,</triggers> <arguments> </arguments> </buildCommand> <buildCommand> <name>org.eclipse.cdt.managedbuilder.core.ScannerConfigBuilder</name> <triggers>full,incremental,</triggers> <arguments> </arguments> </buildCommand> </buildSpec> <natures> <nature>org.eclipse.cdt.core.cnature</nature> <nature>org.eclipse.cdt.managedbuilder.core.managedBuildNature</nature> <nature>org.eclipse.cdt.managedbuilder.core.ScannerConfigNature</nature> <nature>fr.ac6.mcu.ide.core.MCUProjectNature</nature> <nature>fr.ac6.mcu.ide.core.MCUSingleCoreProjectNature</nature> </natures> <linkedResources> <link> <name>Common</name> <type>2</type> <locationURI>OSTC4/Common</locationURI> </link> <link> <name>Discovery</name> <type>2</type> <locationURI>OSTC4/Discovery</locationURI> </link> </linkedResources> <variableList> <variable> <name>OSTC4</name> <value>$%7BWORKSPACE_LOC%7D/ostc4</value> </variable> </variableList> </projectDescription>