view Discovery/Inc/vpm.h @ 913:5f38cf765193 Evo_2_23 tip

Adapted limit for better gas warning: The Better gas warning was shown more or less when the diver already passed the change depth. In the new version the better gas option is provided when the diver reachs the major digit depth (e.g. 22.9m instead 20.0m). This change does not effect the gas change depth used for deco calculation.
author Ideenmodellierer
date Tue, 15 Oct 2024 21:10:45 +0200
parents 46a21ff3f5ab
children
line wrap: on
line source

///////////////////////////////////////////////////////////////////////////////
/// -*- coding: UTF-8 -*-
///
/// \file   Discovery/Inc/vpm.h
/// \brief  Varying Permeability Model (VPM) Decompression Program
/// \author Heinrichs Weikamp
/// \date   23.04.2013
///
/// $Id$
///////////////////////////////////////////////////////////////////////////////
/// \par Copyright (c) 2014-2018 Heinrichs Weikamp gmbh
///
///     This program is free software: you can redistribute it and/or modify
///     it under the terms of the GNU General Public License as published by
///     the Free Software Foundation, either version 3 of the License, or
///     (at your option) any later version.
///
///     This program is distributed in the hope that it will be useful,
///     but WITHOUT ANY WARRANTY; without even the implied warranty of
///     MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
///     GNU General Public License for more details.
///
///     You should have received a copy of the GNU General Public License
///     along with this program.  If not, see <http://www.gnu.org/licenses/>.
//////////////////////////////////////////////////////////////////////////////

#ifndef VPM_H
#define VPM_H

#include "buehlmann.h"
#include "data_central.h"

extern long vpm_time_calc_begin;
enum DECOLIST{DECOSTOPS,FUTURESTOPS,BAILOUTSTOPS, OFF = -1}; // order is important!!
enum VPM_CALC_STATUS{CALC_END, CALC_BEGIN, CALC_CRITICAL, CALC_FINAL_DECO, CALC_NDL };

typedef enum
{
	VPM_TABLE_INIT = 0,
	VPM_TABLE_ACTIVE,
	VPM_TABLE_WARNING,
	VPM_TABLE_MISSED
} SvpmTableState;

float schreiner_equation__2(float *initial_inspired_gas_pressure,float *rate_change_insp_gas_pressure,float *interval_time_minutes,  const float *gas_time_constant,float *initial_gas_pressure);

int  vpm_calc(SLifeData* pINPUT, SDiveSettings* diveSettings, SVpm* pVPM, SDecoinfo*  pDECOINFO, int calc_what);
void  vpm_saturation_after_ascent(SLifeData* input);
extern  const float helium_time_constant[16];
extern  const float nitrogen_time_constant[16];

float vpm_get_CNS(void);

void vpm_table_init(void);
uint8_t vpm_get_decozone(void);
SvpmTableState vpm_get_TableState(void);


#endif /* VPM_H */