view Small_CPU/Inc/uartProtocol_Sentinel.h @ 998:5a690195b6b7 GasConsumption

Added dual operation of scrubber timers: In the previous version only one scrubber timer could be selected for operation. In the new version the activation of both timers is possible. In that case both timers will be displayed as well. To enable this a new activation item has been added to the scrubber menu.
author Ideenmodellierer
date Wed, 23 Apr 2025 14:52:03 +0200
parents c3dd461ca3f9
children
line wrap: on
line source

/**
  ******************************************************************************
  * @file    uartProtocol_Sentinel.h
  * @author  heinrichs weikamp gmbh
  * @version V0.0.1
  * @date    15-Jan-2024
  * @brief	 Interface functionality read data from Sentinel rebreather
  *
  @verbatim
  ==============================================================================
                        ##### How to use #####
  ==============================================================================
  @endverbatim
  ******************************************************************************
  * @attention
  *
  * <h2><center>&copy; COPYRIGHT(c) 2014 heinrichs weikamp</center></h2>
  *
  ******************************************************************************
  */

/* Define to prevent recursive inclusion -------------------------------------*/
#ifndef UART_PROTOCOL_SENTINEL_H
#define UART_PROTOCOL_SENTINEL_H

#ifdef __cplusplus
 extern "C" {
#endif

/* Includes ------------------------------------------------------------------*/
#include "configuration.h"
#include "stm32f4xx_hal.h"

 typedef enum
  {
	UART_SENTINEL_INIT = 0,		/* Default Status for every sensor type */
	UART_SENTINEL_IDLE,			/* sensor detected and no communication pending */
	UART_SENTINEL_ERROR,
  	UART_SENTINEL_OPERATING,		/* normal operation */
  } uartSentinelStatus_t;

  typedef enum
  {
  	SENTRX_Ready= 0,					/* Initial state */
 	SENTRX_DetectStart,					/* validate start byte */
 	SENTRX_SelectData,					/* Data contained in this frame */
  	SENTRX_Data0,						/* Process incoming data */
 	SENTRX_Data1,
 	SENTRX_Data2,
 	SENTRX_Data3,
 	SENTRX_Data4,
 	SENTRX_Data5,
 	SENTRX_Data6,
 	SENTRX_Data7,
 	SENTRX_Data8,
 	SENTRX_Data9,
 	SENTRX_Data10,
 	SENTRX_Data11,
 	SENTRX_Data12,
 	SENTRX_DataComplete
  } receiveStateSentinel_t;


void uartSentinel_Control(void);
void uartSentinel_ProcessData(uint8_t data);
uint8_t uartSentinel_isSensorConnected();

#endif /* UART_PROTOCOL_SENTINEL_H */