Mercurial > public > ostc4
view Small_CPU/Inc/uartProtocol_Co2.h @ 998:5a690195b6b7 GasConsumption
Added dual operation of scrubber timers:
In the previous version only one scrubber timer could be selected for operation. In the new version the activation of both timers is possible. In that case both timers will be displayed as well. To enable this a new activation item has been added to the scrubber menu.
| author | Ideenmodellierer |
|---|---|
| date | Wed, 23 Apr 2025 14:52:03 +0200 |
| parents | c3dd461ca3f9 |
| children |
line wrap: on
line source
/** ****************************************************************************** * @file uartProtocol_Co2.h * @author heinrichs weikamp gmbh * @version V0.0.1 * @date 31-Jul-2023 * @brief Interface functionality to handle external, UART based CO2 sensors * @verbatim ============================================================================== ##### How to use ##### ============================================================================== @endverbatim ****************************************************************************** * @attention * * <h2><center>© COPYRIGHT(c) 2014 heinrichs weikamp</center></h2> * ****************************************************************************** */ /* Define to prevent recursive inclusion -------------------------------------*/ #ifndef UART_PROTOCOL_CO2_H #define UART_PROTOCOL_CO2_H #ifdef __cplusplus extern "C" { #endif /* Includes ------------------------------------------------------------------*/ #include "configuration.h" #include "stm32f4xx_hal.h" typedef enum { UART_CO2_INIT = 0, /* Default Status for every sensor type */ UART_CO2_IDLE, /* sensor detected and no communication pending */ UART_CO2_ERROR, UART_CO2_SETUP = 10, /* collecting data needed to be read out of the sensor once at startup */ UART_CO2_OPERATING, /* normal operation */ UART_CO2_CALIBRATE /* request calibration */ } uartCO2Status_t; typedef enum { CO2RX_Ready= 0, /* Initial state */ CO2RX_DetectStart, /* validate start byte */ CO2RX_SelectData, /* Data contained in this frame */ CO2RX_Data0, /* Process incoming data */ CO2RX_Data1, CO2RX_Data2, CO2RX_Data3, CO2RX_Data4, CO2RX_Data5, CO2RX_Data6, CO2RX_Data7, CO2RX_Data8, CO2RX_Data9, CO2RX_Data10, CO2RX_Data11, CO2RX_Data12, CO2RX_DataComplete } receiveStateCO2_t; typedef enum { CO2CMD_MODE_POLL, /* Set operation mode of sensor to polling => only send data if requested */ CO2CMD_MODE_STREAM, /* Set operation mode of sensor to streaming => send data every two seconds */ CO2CMD_CALIBRATE, /* Calibrate sensor */ CO2CMD_GETSCALE, /* Get scaling factor */ CO2CMD_GETDATA /* Read sensor data */ } co2SensorCmd_t; void uartCo2_Control(void); void uartCo2_ProcessData(uint8_t data); void uartCo2_SendCmd(uint8_t CO2Cmd, uint8_t *cmdString, uint8_t *cmdLength); uint8_t uartCo2_isSensorConnected(); #endif /* UART_PROTOCOL_CO2_H */