Added option to select sensitivity of focus detection:
Depending on the location the computer is equiped during dive (arm wet/ dry suite, glove...) it is usefull to adapt the sensitivity of the focus detection. Technical it means the radius of the spot in which direction ray is projected may be changed in size.
The option has been added to the motion control menu.
author | Ideenmodellierer |
---|---|
date | Fri, 12 Feb 2021 21:37:50 +0100 |
parents | 0e7c16dd774d |
children |
line wrap: on
line source
# How to Make an Uploadable Firmware File for the OSTC4 # Generated BIN files from the SMT32 Workbench need modification in order to be installed via the OSTC Companion onto the OSTC4. ## Build Command Line Tools ## These can be found in /ostc4pack (For Windows, CPP sources available) ## Run the Tools Manually ## 1. Copy generated BIN files (From the Release or debug directory) into /ostc4pack. Or: Modify .bat files to point to your Release or debug directory. 2. run step1_create_OSTC_RTE_upload.bat and/or step1_create_OSTC4_firmware_upload_bin.bat (Depending on which part you made changes) 3. run step2_create_OSTC4update_bin.bat to create final OSTC4update_xxxxxx.bin, with xxxxxx being the current date in YYMMDD format. This will add important checksums required for the OSTC4's bootloader to accept the file. ## Upload this file with the OSTC Companion software to the OSTC4 ## See http://forum.heinrichsweikamp.com/read.php?7,19186 on how to get and use the "OSTC companion"