view ostc4pack/README.linux @ 519:2c49561c8062

Reset Safety Stop display in case of a new descend: In previous version safety stop was displayed in while the stop depth was reached. The count down was interrupted in case of a new descend but the safety stop was still displayed, blocking the NDL visualization in the big font view. To avoid this scenario a restart function has been added which will return to NDL view in case of a descend > 2m. If just a short drop happend then the countdown will be continued when the safety stop depth is reached again. If that takes more then a minute the safety stop counter is restarted.
author Ideenmodellierer
date Sun, 06 Sep 2020 22:11:51 +0200
parents 9c77cfe8c2b2
children
line wrap: on
line source

README.linux
------------

1. Compile the pack utilities

cd src
make checksum_final_add_fletcher
make OSTC4pack_V4

2. Edit create_full_update_bin.sh

Set BUILD_PATH to the location where you build the individual parts
of the firmware using the OpenSTM23 IDE. 

Set BUILD_TYPE the either Debug or Release (or any other build style you 
defined in the OpenSTM23 IDE).

Set the "build project names" as defined in the OpenSTM23 IDE.

3. Simpy run create_full_update_bin.sh

Run it in the ostc4pack folder of the repository, and a file with name
like OSTC4_<date>.bin is created containg the individual blobs.