view Common/Inc/configuration.h @ 731:2a801cfe23ab

Improvment sensor Autodetection: The sensor type optical has been introduce to enable the OSTC to completly switch of the external interface (voltage + ADC operation) The optical interface is handled via firmware. In addition some states have been added to reset the external power supply and to provide the ADC more time to do its conversation.
author Ideenmodellierer
date Sun, 15 Jan 2023 21:43:33 +0100
parents 1dca3bb187d7
children 7e84ae1513b6
line wrap: on
line source

///////////////////////////////////////////////////////////////////////////////
/// -*- coding: UTF-8 -*-
///
/// \file   Discovery/Inc/configuration.h
/// \brief  Header file for variant specific firmware adaptations at compile time
/// \author heinrichs weikamp gmbh
/// \date   29-February-2020
///
/// $Id$
///////////////////////////////////////////////////////////////////////////////
/// \par Copyright (c) 2014-2020 Heinrichs Weikamp gmbh
///
///     This program is free software: you can redistribute it and/or modify
///     it under the terms of the GNU General Public License as published by
///     the Free Software Foundation, either version 3 of the License, or
///     (at your option) any later version.
///
///     This program is distributed in the hope that it will be useful,
///     but WITHOUT ANY WARRANTY; without even the implied warranty of
///     MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
///     GNU General Public License for more details.
///
///     You should have received a copy of the GNU General Public License
///     along with this program.  If not, see <http://www.gnu.org/licenses/>.
//////////////////////////////////////////////////////////////////////////////

#ifndef CONFIGURATION_HEADER
#define CONFIGURATION_HEADER

/* Enable this to make the simulator write a logbook entry */
/* #define SIM_WRITES_LOGBOOK 1 */

/* Enable this for support of optical bottle pressure interface */
/* #define ENABLE_BOTTLE_SENSOR */

/* Enable this to show voltage in parallel to charge state */
/* #define ALWAYS_SHOW_VOLTAGE */

/* Enable this to skip coplete scan of dive log during startup */
#define TRUST_LOG_CONSISTENCY

/* Enable this to transfer additional data list last dive ID and last sample index during raw data requests */
/* define SEND_DATA_DETAILS */

/* Enable to activate a menu item in reset menu which provide sample ring analysis / repair functionality */
/* #define ENABLE_ANALYSE_SAMPLES */

/* Enable to have access to the debug view options (turn on / off via menu instead of compile switch) */
/* #define HAVE_DEBUG_VIEW */

/* Enable to have access to the motion control selection menu */
/* #define ENABLE_MOTION_CONTROL */

/* Enable to have option to hide not needed gases from dive views */
/* #define ENABLE_UNUSED_GAS_HIDING */

/* Enable to have the new T3 profile view available */
#define ENABLE_T3_PROFILE_VIEW

/* Enable to have PPO2 adjustments in T3 sensor view during dive simulation */
/* #define ENABLE_T3_PPO_SIM */

/* Enable to have PSCR functionality available */
#define ENABLE_PSCR_MODE

/* Enable to have CO2 sensor functionality available */
#define ENABLE_CO2_SUPPORT

/* Enable to have Sentinel rebreather interface available */
/* #define ENABLE_SENTINEL_MODE */

/* Enable if you are using sensors with a voltage range 8..16 mV at surface / air level */
#define ENABLE_ALTERNATIVE_SENSORTYP

/* Enable if an external pressure sensor is connected at ADC channel3 (used for sensor verification) */
/* #define ENABLE_EXTERNAL_PRESSURE */

#endif