view Small_CPU/Inc/uartProtocol_Sentinel.h @ 1082:1aa45000f92c Icon_Integration tip

Added configuration menu for HUD functions: The V1 HUD has 4 functions (holes) which may be realized by one or two LEDs. The functions (like ppo2 monitoring or ascent speed) may be configurated by the diver using the HUD menu. The functions which may be selected depend on the HW configuration (e.g. the connected sensors) and the number of LEDs which are needed to realize the function. The previous HUD test implementation may still be activate usind the compile switch ENABLE_HUD_TESTING
author Ideenmodellierer
date Sun, 15 Mar 2026 21:40:35 +0100
parents 785772303f9c
children
line wrap: on
line source

/**
  ******************************************************************************
  * @file    uartProtocol_Sentinel.h
  * @author  heinrichs weikamp gmbh
  * @version V0.0.1
  * @date    15-Jan-2024
  * @brief	 Interface functionality read data from Sentinel rebreather
  *
  @verbatim
  ==============================================================================
                        ##### How to use #####
  ==============================================================================
  @endverbatim
  ******************************************************************************
  * @attention
  *
  * <h2><center>&copy; COPYRIGHT(c) 2014 heinrichs weikamp</center></h2>
  *
  ******************************************************************************
  */

/* Define to prevent recursive inclusion -------------------------------------*/
#ifndef UART_PROTOCOL_SENTINEL_H
#define UART_PROTOCOL_SENTINEL_H

#ifdef __cplusplus
 extern "C" {
#endif

/* Includes ------------------------------------------------------------------*/
#include "configuration.h"
#include "stm32f4xx_hal.h"

/* Bit flags for different sensor types provided by Sentinel or Red Head/Bare */

#define SENTINEL_O2			0x01
#define SENTINEL_CO2		0x02
#define SENTINEL_PRESSURE	0x04
#define SENTINEL_TEMPSTICK	0x08



#define	UART_SENTINEL_O2_P 	'T'				/* Primary O2 sensor */
#define	UART_SENTINEL_O2_S	'S'				/* Secondary O2 sensor */
#define	UART_SENTINEL_PRESSURE_O2 	'I'		/* O2 pressure */
#define	UART_SENTINEL_PRESSURE_D	'J'		/* Diluent pressure */
#define	UART_SENTINEL_TEMPSTICK		'Y'		/* Sector value of the tempstick */

 typedef enum
  {
	UART_SENTINEL_INIT = 0,		/* Default Status for every sensor type */
	UART_SENTINEL_IDLE,			/* sensor detected and no communication pending */
	UART_SENTINEL_ERROR,
  	UART_SENTINEL_OPERATING,		/* normal operation */
  } uartSentinelStatus_t;

  typedef enum
  {
  	SENTRX_Ready= 0,					/* Initial state */
 	SENTRX_DetectStart,					/* validate start byte */
 	SENTRX_SelectData,					/* Data contained in this frame */
  	SENTRX_Data0,						/* Process incoming data */
 	SENTRX_Data1,
 	SENTRX_Data2,
 	SENTRX_Data3,
 	SENTRX_Data4,
 	SENTRX_Data5,
 	SENTRX_Data6,
 	SENTRX_Data7,
 	SENTRX_Data8,
 	SENTRX_Data9,
 	SENTRX_Data10,
 	SENTRX_CheckSum,
 	SENTRX_DataComplete
  } receiveStateSentinel_t;


void uartSentinel_Control(void);
void uartSentinel_ProcessData(uint8_t data);
uint8_t uartSentinel_isSensorConnected();

#endif /* UART_PROTOCOL_SENTINEL_H */