view Discovery/Inc/unit.h @ 837:18946846b95b Evo_2_23

Bugfixes and code cleanup for BF views: BF views gauge and apnoe were using "dive computer" T3 view functions which caused some problem because these legacy views were not intended to work with customer view selection. A switch condition has been added to skip these kind of functions in case a design other T3 is in use. Another potential problem was that there were two definitions for T3 and T7 views which were basically the same. If they wold not be the same the switching functionality wold not work properly. To avoid this problem in futur the arrays have been merged => the view are handled sing the (newer) cv_view arrays instead of the standard_views which were in used before the user could the views which should be shown.
author ideenmodellierer
date Wed, 27 Dec 2023 19:37:17 +0100
parents 269e57ac4e56
children
line wrap: on
line source

///////////////////////////////////////////////////////////////////////////////
/// -*- coding: UTF-8 -*-
///
/// \file   Discovery/Inc/unit.h
/// \brief  input to meter/celsius or feet/farenheit
/// \author heinrichs weikamp gmbh
/// \date   24-Feb-2015
///
/// $Id$
///////////////////////////////////////////////////////////////////////////////
/// \par Copyright (c) 2014-2018 Heinrichs Weikamp gmbh
///
///     This program is free software: you can redistribute it and/or modify
///     it under the terms of the GNU General Public License as published by
///     the Free Software Foundation, either version 3 of the License, or
///     (at your option) any later version.
///
///     This program is distributed in the hope that it will be useful,
///     but WITHOUT ANY WARRANTY; without even the implied warranty of
///     MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
///     GNU General Public License for more details.
///
///     You should have received a copy of the GNU General Public License
///     along with this program.  If not, see <http://www.gnu.org/licenses/>.
//////////////////////////////////////////////////////////////////////////////

/* Define to prevent recursive inclusion -------------------------------------*/
#ifndef UNIT_H
#define UNIT_H

#ifdef __cplusplus
 extern "C" {
#endif

/* Includes ------------------------------------------------------------------*/
#include "stm32f4xx_hal.h"

/** @addtogroup Template
	* @{
	*/

/* Exported variables --------------------------------------------------------*/


/* Exported functions --------------------------------------------------------*/
float unit_depth_float(float input_meter);
uint16_t unit_depth_integer(uint16_t input_meter);
float unit_temperature_float(float input_celsius);
int16_t unit_temperature_integer(int16_t input_celsius);
uint16_t unit_speed_integer(uint16_t input_meterPerMinute);
int unit_SeaLevelRelation_integer(int input_atmospheric_mbar);
char unit_depth_char1(void);
char unit_depth_char2(void);
char unit_depth_char1_T105(void);
char unit_depth_char2_T105(void);

#ifdef __cplusplus
}
#endif

#endif /* UNIT_H */