view Common/Inc/decom.h @ 837:18946846b95b Evo_2_23

Bugfixes and code cleanup for BF views: BF views gauge and apnoe were using "dive computer" T3 view functions which caused some problem because these legacy views were not intended to work with customer view selection. A switch condition has been added to skip these kind of functions in case a design other T3 is in use. Another potential problem was that there were two definitions for T3 and T7 views which were basically the same. If they wold not be the same the switching functionality wold not work properly. To avoid this problem in futur the arrays have been merged => the view are handled sing the (newer) cv_view arrays instead of the standard_views which were in used before the user could the views which should be shown.
author ideenmodellierer
date Wed, 27 Dec 2023 19:37:17 +0100
parents 1b995079c045
children
line wrap: on
line source

///////////////////////////////////////////////////////////////////////////////
/// -*- coding: UTF-8 -*-
///
/// \file   Common/Inc/decom.h
/// \brief  This code is used to calculate desat, calculated by RTE and send to Firmware
/// \author Heinrichs Weikamp
/// \date   22-Feb-2016
///
/// $Id$
///////////////////////////////////////////////////////////////////////////////
/// \par Copyright (c) 2014-2018 Heinrichs Weikamp gmbh
///
///     This program is free software: you can redistribute it and/or modify
///     it under the terms of the GNU General Public License as published by
///     the Free Software Foundation, either version 3 of the License, or
///     (at your option) any later version.
///
///     This program is distributed in the hope that it will be useful,
///     but WITHOUT ANY WARRANTY; without even the implied warranty of
///     MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
///     GNU General Public License for more details.
///
///     You should have received a copy of the GNU General Public License
///     along with this program.  If not, see <http://www.gnu.org/licenses/>.
//////////////////////////////////////////////////////////////////////////////

#ifndef DECOM_H
#define DECOM_H

#include "data_central.h"

#	define	WATER_VAPOUR_PRESSURE	(0.0493f) // Schreiner 1971

void decom_get_inert_gases(const float ambient_pressure_bar,const SGas* pGas, float* fraction_nitrogen, float* fraction_helium );
void decom_tissues_exposure(int period_in_seconds, SLifeData* pLifeData);
void decom_tissues_exposure2(int period_in_seconds, SGas* pActualGas, float pressure_ambient_bar, float *tissue_N2_selected_stage, float *tissue_He_selected_stage);
float decom_schreiner_equation(float *initial_inspired_gas_pressure, float *rate_change_insp_gas_pressure, float *interval_time_minutes, const float *gas_time_constant, float *initial_gas_pressure);
void decom_reset_with_1000mbar(SLifeData * pLifeData);
void decom_reset_with_ambientmbar(float ambient, SLifeData * pLifeData);

void decom_tissues_exposure_stage_schreiner(int period_in_seconds, SGas* pGas, float  starting_ambient_pressure_bar, float ending_ambient_pressure_bar,
																		 float* pTissue_nitrogen_bar, float* pTissue_helium_bar);
void decom_CreateGasChangeList(SDiveSettings* pInput, const SLifeData* lifeData);
uint8_t decom_tissue_test_tolerance(float* Tissue_nitrogen_bar, float* Tissue_helium_bar, float GF_value, float depth_in_bar_absolute);
void decom_tissues_desaturation_time(const SLifeData* pLifeData, SLifeData2* pOutput);
void test_decom_CreateGasChangeList(void);

float decom_calc_ppO2(const float ambiant_pressure_bar, const SGas* pGas);
float decom_calc_SimppO2(float ambiant_pressure_bar, const SGas* pGas);
float decom_calc_SimppO2_O2based(float ambiant_pressure_bar, uint8_t O2PerCent, float factor);
void decom_oxygen_calculate_otu(float* oxygen_otu, float pressure_oxygen_real);
void decom_oxygen_calculate_otu_degrade(float* oxygen_otu, long seconds_since_last_dive);
void decom_oxygen_calculate_cns_degrade(float* oxygen_cns, long seconds_since_last_dive);
void decom_oxygen_calculate_cns(float* oxygen_cns, float pressure_oxygen_real);
void decom_oxygen_calculate_cns_stage_SchreinerStyle(int period_in_seconds, SGas* pGas, float  starting_ambient_pressure_bar, float ending_ambient_pressure_bar, float* oxygen_cns);
void decom_oxygen_calculate_cns_exposure(int period_in_seconds, SGas* pActualGas, float pressure_ambient_bar, float* oxygen_cns);
uint8_t decom_get_actual_deco_stop(SDiveState* pDiveState);

// wird nur in smallCPU verwendet:
int decom_calc_desaturation_time(float* Tissue_nitrogen_bar, float* Tissue_helium_bar, float surface_pressure_bar);

#endif /* DECOM_H */