view wiki/Make Firmware File.md @ 845:17d9d6eddd8d Evo_2_23

Added new PreDiveCheck info page: In case a DiveO2 sensor is connected to the OSTC than the values of the DiveO2 internal pressure and temperature sensors may be used for predive checks. The pressure sensors is used for over / under pressure test and the values are visualized using a graph to make it easier to check if the pressure keeps stable. The temperature measurement gives an indication if the scrubber is getting active. This view is highly dependend on the surface temperature but may be useful e.g. for diving in european area. In addition the values ofthe connected sensors are shown.
author Ideenmodellierer
date Sun, 21 Jan 2024 22:24:36 +0100
parents 0e7c16dd774d
children
line wrap: on
line source

# How to Make an Uploadable Firmware File for the OSTC4 #

Generated BIN files from the SMT32 Workbench need modification in order to be installed via the OSTC Companion onto the OSTC4. 

## Build Command Line Tools ##

These can be found in /ostc4pack (For Windows, CPP sources available)

## Run the Tools Manually ##

1. Copy generated BIN files (From the Release or debug directory) into /ostc4pack. Or: Modify .bat files to point to your Release or debug directory.
2. run step1_create_OSTC_RTE_upload.bat and/or step1_create_OSTC4_firmware_upload_bin.bat (Depending on which part you made changes)
3. run step2_create_OSTC4update_bin.bat to create final OSTC4update_xxxxxx.bin, with xxxxxx being the current date in YYMMDD format. This will add important checksums required for the OSTC4's bootloader to accept the file.

## Upload this file with the OSTC Companion software to the OSTC4 ##

See http://forum.heinrichsweikamp.com/read.php?7,19186 on how to get and use the "OSTC companion"