view Small_CPU/Inc/uartProtocol_O2.h @ 1027:158100a84ebd GasConsumption

New profile feature: In the past the OSTC provide just one instance for settings. If for example a diver switched from OC to CCR configuration several settings had to be modified. To improve this and to be more flexible in adapting the OSTC to differend dive scenarions the usage of up to 4 profiles has beem introduced. The profiles are copies of the common settings but stored in a separate, previously not used, flash section => no impact to existings settings handling. For access to the profiles the existing setting flash functions are reused. To enable this a parameter war introduced which defines the target of the operation (common settings or profiles).
author Ideenmodellierer
date Sun, 07 Sep 2025 19:03:44 +0200
parents e9eba334b942
children
line wrap: on
line source

/**
  ******************************************************************************
  * @file    uartProtocol_O2.h
  * @author  heinrichs weikamp gmbh
  * @version V0.0.1
  * @date    18-Jun-2023
  * @brief	 Interface functionality to handle external, UART based O2 sensors
  *
  @verbatim
  ==============================================================================
                        ##### How to use #####
  ==============================================================================
  @endverbatim
  ******************************************************************************
  * @attention
  *
  * <h2><center>&copy; COPYRIGHT(c) 2014 heinrichs weikamp</center></h2>
  *
  ******************************************************************************
  */

/* Define to prevent recursive inclusion -------------------------------------*/
#ifndef UART_PROTOCOL_O2_H
#define UART_PROTOCOL_O2_H

#ifdef __cplusplus
 extern "C" {
#endif

/* Includes ------------------------------------------------------------------*/
#include "configuration.h"
#include "stm32f4xx_hal.h"

 typedef enum
 {
 	UART_COMMON_INIT = 0,	/* Default Status for every sensor type */
	UART_COMMON_IDLE,		/* sensor detected and no communication pending */
	UART_COMMON_ERROR,		/* Error message received from sensor */
 } uartCommonStatus_t;

 typedef enum
 {
	UART_O2_INIT = UART_COMMON_INIT,		/* Default Status for every sensor type */
	UART_O2_IDLE = UART_COMMON_IDLE,		/* sensor detected and no communication pending */
	UART_O2_ERROR = UART_COMMON_ERROR,		/* Error message received from sensor */
 	UART_O2_CHECK,							/* send blink command and check if sensor answers */
 	UART_O2_REQ_INFO,						/* request information about available internal sensors of sensor */
	UART_O2_REQ_ID,							/* request ID of sensor */
 	UART_O2_REQ_O2,							/* O2 value has been requested and is in receiption progress */
	UART_O2_REQ_RAW,						/* Request O2 and extended raw data */
 } uartO2Status_t;


 typedef enum
  {
	O2RX_IDLE = 0,			/* no reception pending */
	O2RX_CONFIRM,			/* check the command echo */
	O2RX_GETNR,				/* extract the sensor number */
	O2RX_GETO2,				/* extract the ppo2 */
	O2RX_GETTEMP,			/* extract the temperature */
	O2RX_GETSTATUS,			/* extract the sensor status */
	O2RX_GETTYPE,			/* extract the sensor type (should be 8) */
	O2RX_GETCHANNEL,		/* extract the number of sensor channels (should be 1) */
	O2RX_GETVERSION,		/* extract the sensor version */
	O2RX_GETSUBSENSORS,		/* extract the available measures (O2, temperature, humidity etc) */
	O2RX_GETDPHI,			/* extract phase shift */
	O2RX_INTENSITY,			/* extract intensity of signal */
	O2RX_AMBIENTLIGHT,		/* extract the intensity of the ambient light */
	O2RX_PRESSURE,			/* extract pressure within the sensor housing */
	O2RX_HUMIDITY			/* extract humidity within the sensor housing */
  } uartO2RxState_t;

void uartO2_Control(void);
void uartO2_ProcessData(uint8_t data);
void uartO2_SetChannel(uint8_t channel);
uint8_t uartO2_isSensorConnected();




#endif /* EXTERNAL_INTERFACE_H */