Bugfix initialisation of surface pressure: A reset of the RTE less than one minute before a dive starts may cause problems in the depth calculation because the default pressure is not set yet. To avoid this the first measured pressure value will now be used as stable surface pressure to close the gap till the stable surface pressure is evaluated.
author Ideenmodellierer
date Tue, 07 May 2024 21:12:37 +0200
parents 0e7c16dd774d
children
line wrap: on
line source

# How to Make an Uploadable Firmware File for the OSTC4 #

Generated BIN files from the SMT32 Workbench need modification in order to be installed via the OSTC Companion onto the OSTC4. 

## Build Command Line Tools ##

These can be found in /ostc4pack (For Windows, CPP sources available)

## Run the Tools Manually ##

1. Copy generated BIN files (From the Release or debug directory) into /ostc4pack. Or: Modify .bat files to point to your Release or debug directory.
2. run step1_create_OSTC_RTE_upload.bat and/or step1_create_OSTC4_firmware_upload_bin.bat (Depending on which part you made changes)
3. run step2_create_OSTC4update_bin.bat to create final OSTC4update_xxxxxx.bin, with xxxxxx being the current date in YYMMDD format. This will add important checksums required for the OSTC4's bootloader to accept the file.

## Upload this file with the OSTC Companion software to the OSTC4 ##

See http://forum.heinrichsweikamp.com/read.php?7,19186 on how to get and use the "OSTC companion"