view Small_CPU/Inc/uartProtocol_Co2.h @ 858:08ea8e9d6cfe Evo_2_23

Bugfix initialisation of surface pressure: A reset of the RTE less than one minute before a dive starts may cause problems in the depth calculation because the default pressure is not set yet. To avoid this the first measured pressure value will now be used as stable surface pressure to close the gap till the stable surface pressure is evaluated.
author Ideenmodellierer
date Tue, 07 May 2024 21:12:37 +0200
parents c3dd461ca3f9
children
line wrap: on
line source

/**
  ******************************************************************************
  * @file    uartProtocol_Co2.h
  * @author  heinrichs weikamp gmbh
  * @version V0.0.1
  * @date    31-Jul-2023
  * @brief	 Interface functionality to handle external, UART based CO2 sensors
  *
  @verbatim
  ==============================================================================
                        ##### How to use #####
  ==============================================================================
  @endverbatim
  ******************************************************************************
  * @attention
  *
  * <h2><center>&copy; COPYRIGHT(c) 2014 heinrichs weikamp</center></h2>
  *
  ******************************************************************************
  */

/* Define to prevent recursive inclusion -------------------------------------*/
#ifndef UART_PROTOCOL_CO2_H
#define UART_PROTOCOL_CO2_H

#ifdef __cplusplus
 extern "C" {
#endif

/* Includes ------------------------------------------------------------------*/
#include "configuration.h"
#include "stm32f4xx_hal.h"

 typedef enum
  {
	UART_CO2_INIT = 0,		/* Default Status for every sensor type */
	UART_CO2_IDLE,			/* sensor detected and no communication pending */
	UART_CO2_ERROR,
 	UART_CO2_SETUP = 10,	/* collecting data needed to be read out of the sensor once at startup */
  	UART_CO2_OPERATING,		/* normal operation */
	UART_CO2_CALIBRATE		/* request calibration */
  } uartCO2Status_t;

  typedef enum
  {
  	CO2RX_Ready= 0,					/* Initial state */
 	CO2RX_DetectStart,					/* validate start byte */
 	CO2RX_SelectData,					/* Data contained in this frame */
  	CO2RX_Data0,						/* Process incoming data */
 	CO2RX_Data1,
 	CO2RX_Data2,
 	CO2RX_Data3,
 	CO2RX_Data4,
 	CO2RX_Data5,
 	CO2RX_Data6,
 	CO2RX_Data7,
 	CO2RX_Data8,
 	CO2RX_Data9,
 	CO2RX_Data10,
 	CO2RX_Data11,
 	CO2RX_Data12,
 	CO2RX_DataComplete
  } receiveStateCO2_t;


 typedef enum
 {
 	CO2CMD_MODE_POLL,		/* Set operation mode of sensor to polling => only send data if requested */
 	CO2CMD_MODE_STREAM,		/* Set operation mode of sensor to streaming => send data every two seconds */
 	CO2CMD_CALIBRATE,		/* Calibrate sensor */
 	CO2CMD_GETSCALE,		/* Get scaling factor */
 	CO2CMD_GETDATA			/* Read sensor data */
 } co2SensorCmd_t;


void uartCo2_Control(void);
void uartCo2_ProcessData(uint8_t data);
void uartCo2_SendCmd(uint8_t CO2Cmd, uint8_t *cmdString, uint8_t *cmdLength);
uint8_t uartCo2_isSensorConnected();

#endif /* UART_PROTOCOL_CO2_H */